![Ocean OWDI 9614 WT S Скачать руководство пользователя страница 34](http://html2.mh-extra.com/html/ocean/owdi-9614-wt-s/owdi-9614-wt-s_service-manual_5137961034.webp)
Page 34
8.2 Circulation Pump*
The component is used for circulation of water
inside the drum in order to increase washing
performance.
Circulation Pump
Technical features
Nominal voltage
220 - 240 V
Frequence
50 Hz
Resistor (ci)
169,5 Ω (±5%)
Testing component
Check the resistance value on the component with multi meter as shown below.
Resistance value should be between 160- 180 Ω
You can determine the ohm value by measuring from the red cable at 5th and red cable at 12th
position in the small socket (refer wiring diagram in section 12) as shown below figure. Resistance
value should be between 160- 180 Ω
Содержание OWDI 9614 WT S
Страница 10: ...10 With TJ models...
Страница 11: ...11 Without TJ models...
Страница 47: ...Page 47 9 Wiring Diagram VWM 10603_JD SIZ_BLDC_WD_Floating Hook Door...
Страница 48: ...48 VWM 10636_JD SIZ _ BLDC_WD_PTC_Solenoid Door...
Страница 49: ...49 T Series User nterface User Connection Diagram...