![Ocean OWDI 9614 WT S Скачать руководство пользователя страница 51](http://html2.mh-extra.com/html/ocean/owdi-9614-wt-s/owdi-9614-wt-s_service-manual_5137961051.webp)
51
E02
Lack of Water
Do not run WM till enviromental conditions in
product specifications are met
Do not run WM till required plumping operations are
done and water pressure is in required range.
Open the tap
Refit loose sockets/connectors, replace cable
group if connectors/sockets are worn
Replace valve
Replace cable group
Is water inlet tap
opened?
Are environmental
conditions are OK?
Check water pressure, is it
between specified range in
instruction book?
Check PCB socket
connections. Is thee any
loose socket/connector?
Similarly check valve
connectors. Is it loose?
Test valve component as
explained in service
manual. Is valve
component OK?
Redo same valve
test by PCB sockets?
Is it still OK?
Replace PCB
NO
YES
Environmental conditions:
-Voltage range should be in as specified
in instruction book.
-Water pressure should be as specified
in instruction book.
-WM should be grounded properly.
-There should be enough ventilation
space from ground.
-Other environmental specifications and
requirements should be met which are
mentioned in instruction book of WM.
Clean cloggage, replace water inlet
hose/valve if required.
Check waster inlet hose &
valve enterance. Are there
any cloggage in hose and
around filters?
Содержание OWDI 9614 WT S
Страница 10: ...10 With TJ models...
Страница 11: ...11 Without TJ models...
Страница 47: ...Page 47 9 Wiring Diagram VWM 10603_JD SIZ_BLDC_WD_Floating Hook Door...
Страница 48: ...48 VWM 10636_JD SIZ _ BLDC_WD_PTC_Solenoid Door...
Страница 49: ...49 T Series User nterface User Connection Diagram...