TOUCH-OPERATED CERAN COOKER ERROR CODES
Error Code
Description
Potential Cause for
Error
Clearing Error
ER03&
Continuous
signal
sound
Constant use of buttons;
The control unit will silence
automatically after 10
seconds.
Water or cooking utensils
on the glass over the
control unit
Cleaning the appliance surface
ER20
Flash Error
C-Error
Replace the control unit
ER21
To prevent overheating
damaging the electronic
elements,
the control unit interrupts
power after inspection.
When overheated, the
standard algorithm is
reached.
The electronics
environment temperature
still too high.
Wait for cooling down. Check for
overheating.
ER22
Faulty Button evaluation.
The control unit will cut off the
circuit after 3.5 - 7.5 seconds.
Intermittent connection
between short circuit or
button evaluation
Replace the control unit
ER31
Configuration data is
incorrect.
Induction shall be
configured
New configuration
ER36
NTC value is incorrect
NTC open or shorted
Replace the control unit
ER40
Secondary operational voltage
is low with respect to the
defined low voltage at least for
5 seconds
(1.8V<Uinterruption<2.9 V)
Primary PTC is
overheated
Remove the Control Unit from the
power unit
ER47
Communication error between
TC and induction
No communication or
faulty communication
Ensure that the connection cable is
installed correctly and that it is in
good condition.
U400
Secondary voltage of the
power unit to high
(primary>300 V). The control
unit shall turn off after buzzing
for 1 second.
The control unit
connection is faulty.
Connect to the mains supply
correctly.
E2
Overheating of the induction
coils
Needs to cool down
E5
Error on filter board
Replace the filter board
E6
Error on power unit
Replace the power unit.
E9
Coil temperature sensor
defective
Change temperature sensor.
EN
43
Содержание OGHF 64 I PRO SV
Страница 1: ...COUNTERTOP BUILT IN COOKER GAS AND ELECTRIC SERVICE MANUAL COOKING HOB OGHF 64 I PRO SV...
Страница 8: ...GAS HOB GROUPS 8 EN...
Страница 28: ...ELECTRIC COOKER GROUPS 28 EN...
Страница 41: ...4a interior black red TERMINAL BLOCK blue 2 brown blue 2 orange orange blue brown 304 board EN I 41...