Ocean Optics LS-450 Series Скачать руководство пользователя страница 4

 

 

LS-450 Series Blue LED Pulsed Light Sources 

LS-450 Series Blue LED Pulsed Light Sources 

4 

R-LS-450 Rack-mount Blue LED Pulsed Light Sources 

The R-LS-450 Blue LED Pulsed Light Source is the rack-
mount version of the LS-450.  You can configure the R-LS-
450 to operate in continuous wave mode via manual 
operation as well as through the software.  You can also 
configure the R-LS-450 to operate in pulsed mode through 
manual operation and through the software. 

Ocean Optics ships the R-LS-450 with following jumper 
configuration: 

• 

Jumper over pins in JP1 

• 

Jumper over manual pins in JP3 

• 

Jumper over 2

10

 pins in JP2 (fastest pulse rate 

available) 

To modify these jumper settings, consult the Operation 
section that follows. 

Operation 

You can configure the lamp using a switch and three jumper blocks on the circuit board of the R-LS-450 and, if 
applicable, one jumper block on the S2000 spectrometer. The following section details the variety of 
configurations available with the R-LS-450. You need to determine the best mode of operation for your setup and 
configure your system appropriately. 

S1 Switch 

The S1 switch is a three-position switch on the R-LS-450.  The switch can be moved into the following positions: 

• 

Continuous wave operation 

• 

Off 

• 

Pulsed operation 

Note:  If you are using a USB-based spectrometer, instructions specifically for the S2000 spectrometer will not 

apply. 

Jumper Block 1 (JP1) 

JP1 consists of only one set of pins.  If you configure other jumper blocks correctly, a jumper over JP1 allows you 
to turn the R-LS-450 on and off via the Strobe Enable/Disable feature in OOIBase32. This feature is only available 
with a “J” or later version of the S2000 spectrometer (USB-based spectrometers have a fixed pulse rate of 1 ms).  

Note:  To find out if you have a J-series or later S2000, look at the third character in your S2000 serial number. 

Jumper Block 2 (JP2) 

JP2 consists of nine sets of pins. You can configure the number of pulses per seconds by changing which pins 
are jumped in JP2. However, pulses per second are also dependent on the master frequency of the A/D converter 
you are using. 

The table on the following page contains information on the function of each set of pins in JP2. 

R-LS-450-2 Dual Rack-mount Blue LED Pulsed 

Light Source 

Содержание LS-450 Series

Страница 1: ...d alone Version Included Materials LS 450 light source DB 15 accessory cable Power supply Connecting the LS 450 To connect the LS 450 follow the steps below 1 Plug the wall transformer into a standard...

Страница 2: ...meter See the OOIBase32 Spectrometer Operating Software Online Help System for more information on setting the integration time Note USB based spectrometers automatically flash the lamp once per milli...

Страница 3: ...p Enable option is selected in OOIBase the USB2000 spectrometer will pulse the lamp at 1 msec intervals ensuring a consistent pulse rate regardless of the configured integration time HR2000 1 Obtain a...

Страница 4: ...peration for your setup and configure your system appropriately S1 Switch The S1 switch is a three position switch on the R LS 450 The switch can be moved into the following positions Continuous wave...

Страница 5: ...88 0 976 0 2 10 Divide by 2 10 976 0 1952 0 CS Continuous Strobe Software Controlled Software Controlled Jumper Block 3 JP3 JP3 consists of two sets of pins The jumper position determines the source o...

Страница 6: ...00 You can control the pulses per second of the R LS 450 using JP3 of the S2000 ONLY if the following conditions are met The switch is turned to pulsed mode The pins in JP1 of the R LS 450 are jumpere...

Страница 7: ...times shown in the table below depending on the A D converter you are using S2000 JP3 Pin Row ADC2000 PCI Acceptable Int Times ADC1000 Acceptable Int Times 16 32 64 14 8 16 12 2 4 10 2 4 2 Integration...

Страница 8: ...ic Oxygen Sensor users can conveniently store oxygen and temperature calibration coefficients No External Power Requirements Spectrometer and USB LS 450 draw power from the host PC Temperature Probe C...

Страница 9: ...the USB LS 450 provides unaltered connections to the 10 pin accessory connector on the USB2000 Spectrometer Use this connector to configure external triggering options on the USB2000 when the USB LS...

Страница 10: ...VDC 60 mA 5 VDC Power output minimum 50 W into 600 m fiber 60 W into 600 m fiber Stability 1 0 after 2 minute warm up 1 0 after 2 minute warm up LED drive current 20 mA 5 mA switchable 20 mA 0 15 mA A...

Страница 11: ...Pull the two halves apart gently until they are approximately 1 5 apart This should expose two thin black wires that are holding the unit together These wires connect to a small socket on the LED loc...

Страница 12: ...re the anode and cathode lead pins are located The orientation of the LED should be marked with a white dot on the side of the barrel cathode side OR by differing pin lengths the short pin is the cath...