background image

Ocean Breeze

2951 SE Dominica Terrace, Stuart, Florida 34997

Tel:  772 2200038  [email protected]  http://www.oceanbreezeac.com

Ocean Breeze  Water Cooled Chiller Unit

CW series

Содержание Micro Series

Страница 1: ...Ocean Breeze 2951 SE Dominica Terrace Stuart Florida 34997 Tel 772 2200038 obr oceanbreezeac com http www oceanbreezeac com Ocean Breeze Water Cooled Chiller Unit CW series...

Страница 2: ...Please read the Instructions before attempting any Installation of Ocean Breeze Products Warranty will be VOID if damage to the Chiller occurs...

Страница 3: ...he overall installation process and it is meant to serve as a source of reference The Ocean Breeze Units should be handled by a fully trained and certified Technician with knowledge and has many years...

Страница 4: ...ay cause it to rupture To prevent this a Y Strainer must be installed on the Intake of the Chiller The Flow Switch and Low Pressure Switch will show normal reading It is especially important to make s...

Страница 5: ...Volt 1 Phase 60 Cycle 1 1 4 FT Condensor Water Pump Connecctions 1 1 2 FT Chiller Water Pump Connecctions 3 4 FT Drain Refrigerant Pressure Gauges CW72 Marine Chiller Unit CW72 Marine Chiller Unit 14...

Страница 6: ...1 SE Dominica Terrace Stuart Florida 34997 Tel 772 220 0038 obr oceanbreezeac com http www oceanbreezeac com Chiller Unit 1 2 Pipe 2 Pipe 2 Pipe To Overboard Discharge 1 1 2 Pipe Condensor Manifold IN...

Страница 7: ...http www oceanbreezeac com Reserve Tank Insulated Fan Coil Fan Coil Fan Coil 2 Pipe 2 Pipe 1 1 2 Pipe 2 Pipe 2 Pipe 2 Pipe 2 Pipe Pipe Union Valve 1 1 2 Pipe 2 Tee 1 1 2 Pipe Chiller Pump Chiller 1 D...

Страница 8: ...and certified professional personnel with experience in the HVAC field to do the installation and service of this system Warning Never use Oxygen to pressurize a refrigeration or Air Conditioning Syst...

Страница 9: ...unit will minimize performance and can cause potential damage to the equipment Next locate all needed connections going to the Condenser unit Electrical box Condensate Drain etc Make certain there is...

Страница 10: ...conduit Lay out the Condensate Drain Piping as close to overboard as possible If you are reclaiming condensate water run the pipe to the collection area When the installation of the AC Unit Is complet...

Страница 11: ...ir and condensate drain line with adequate space around the Unit If installing Filter make certain to reserve space for easy access for intake of evaporator Once again keep the interconnections sealed...

Страница 12: ...When mounting is complete and electrical connections are made install the copper refrigerant lines between each of the systems...

Страница 13: ...m in system operation If laying duct work inspect surrounding space and allow ducting to be flat and straight as possible from point to point Use UL Approved Ducting After all of the installation proc...

Страница 14: ......

Страница 15: ...er OFF the Unit and Switch the Phase on the wires connected to the Compressor Contactor Output L1 L2 becomes L2 L1 etc Unit comes Precharged from the factory DO NOT TAMPER with charge Please refer to...

Страница 16: ...Neutral Single phase can be interchangeable however not recommended Wiring in 3 Phase must be absolute L1 to L1 L2 to L2 L3 to L3 Ground to Ground and so forth If Voltage Phase Monitor is installed in...

Страница 17: ...d at the factory up to 600 PSI Nitrogen for One Hour with thermo graphic tools point sensors visual inspection safety pressure impact attire must be worn on this test On the field the low pressure tes...

Страница 18: ...ation If there are any problems correct each problem and test each solution reinspect all problem points to make certain the correction has been made and successful Repeat the above testing procedures...

Страница 19: ...he refrigerant with vacuum pump Allow time for the recovery process 20 minutes per ton to complete The vacuum scale should be up to 30 HG negative pressure at sea level When ready to Power the system...

Страница 20: ...for this system There is a Sight Glass installed on the unit to verify moisture in the system If there are unrelated problems encountered the installer is asked to contact Ocean Breeze at 772 220 003...

Страница 21: ......

Страница 22: ...functioning within operating parameters and the critical charge has been reached the process is complete and the Installer can Power off the system reconnect the bypassed components and retest the sys...

Страница 23: ...for dust Inspect the discharge of the AC unit clean areas that connect to Ducting or if free blowing into the room clean the internal blower wheel Clean every discharge vent with vacuum Clean Digital...

Страница 24: ...isconnected from the wall plate Replace only with fresh Alkaline Batteries Duracell Energizer etc Maintenance will keep your equipment in continue working condition for many years of use For any quest...

Страница 25: ......

Страница 26: ......

Страница 27: ......

Страница 28: ...ular fault present The control will also interrogate the line voltage during the fault condition to avoid short cycling and nuisance trips User Selectable Universal Voltage 190 480 VAC Operating Frequ...

Страница 29: ...0 VAC circuits cut the jumper wire 4 Select the desired time delay 5 Reapply power check operation With application of power the load is energized When the thermostat opens or when there is a loss of...

Страница 30: ...state of the safety switches Power must then be removed for 100 ms and safety switches must be closed in order to reenergize the load upon which the fault light will be off INSTALLATION 1 Disconnect p...

Страница 31: ...O c e a nB r e e z eMi c r oS e r i e s S i n g l eS t a g eD i g i t a l T h e r mo s t a t C o n t r o l...

Страница 32: ...c e a nB r e e z e 2 9 5 1S ED o mi n i c a T e r r a c e S t u a r t F l o r i d a3 4 9 9 7 T e l 7 7 22 2 0 0 0 3 8 o b r o c e a n b r e e z e a c c o m h t t p w w w o c e a n b r e e z e a c c o...

Страница 33: ...d Line and is labeled as Water In Condenser coil can be manufactured so that it can be on either side Seawater in is on the side of the refrigeration liquid line never the discharge side and is labele...

Страница 34: ......

Страница 35: ......

Страница 36: ......

Страница 37: ......

Страница 38: ......

Страница 39: ......

Страница 40: ......

Страница 41: ...Ocean Breeze 2951 SE Dominica Terrace Stuart Florida 34997 Tel 772 2200038 obr oceanbreezeac com http www oceanbreezeac com...

Отзывы: