WARNING:
Y Strainer MUST be installed on Intake of Chiller!
If any debris travels through the connecting pipes from the
Fan Coils to the Braze PlateChannels of the Chiller, the will
cause a "Frozen Spot" on the Plate and may cause it to
rupture.
To prevent this, a Y Strainer must be installed on the Intake
of the Chiller. The Flow Switch and Low Pressure Switch will
show normal reading. It is especially important to make sure
Marine Glycol / Marine Antifreeze to Water ratio is always
maintained at 30% Antifreeze to 70% Water.
Debris entering the Braze Plate Channels will result in
catastrophic damage and will not be covered by the
Warranty.