background image

Product Information Packet

Model TLC-702

Solid State Liquid Chiller with Integral TC-3300

Temperature Control and Custom Front Panel

Part #6-A0D2-0-003

Thank you for your purchase. Information has been inclosed regarding the
installation, specifications, and wiring af your solid state assembly.

Please read and follow all instructions carefully before installation. Only
qualified technicians should install this equipment.

If you have any questions with your equipment, please do not hesitate to call
us toll free at (888) TECA-USA (832-2872), we will be happy to assist. We
are open from 8:00 am to 4:30 pm Central Time.

Included in this packet you will find:

Getting Started

Product Literature and Specifications

Wiring Drawing # SK991205

Temperature Control Literature Set-Up and Communications Information

Warranty Information

TC-3300 Manual

Содержание 6-A0D2-0-000

Страница 1: ...all instructions carefully before installation Only qualified technicians should install this equipment If you have any questions with your equipment please do not hesitate to call us toll free at 888 TECA USA 832 2872 we will be happy to assist We are open from 8 00 am to 4 30 pm Central Time Included in this packet you will find Getting Started Product Literature and Specifications Wiring Drawin...

Страница 2: ...oir is topped off Connect the power cord to an appropriate outlet The power cord must be connected to a receptacle protected by a circuit protected per local and or national codes While you are filling the external lines position the supply quick connect upwards See Figure A This will assist in removing air trapped in the lines At this point depress the power switch on the front panel to turn the ...

Страница 3: ......

Страница 4: ......

Страница 5: ......

Страница 6: ... sc 10 inpt tc t unit c Note uEr value is preset and can not be changed however it provides access to LEVEL 4 Press and hold UP and DOWN buttons for 10 seconds to access LEVEL 4 LEVEL C only visible when COMMS option fitted Set SP1 main temperature set point to 10 C To access the set up menu push and hold UP and DOWN buttons simultaneously for 3 seconds Press and hold UP or DOWN button to navigate...

Страница 7: ...b nonE disp 0 1 hisc 70 Lo sc 10 inpt tc t unit c Note uEr value is preset and can not be changed however it provides access to LEVEL 4 Press and hold UP and DOWN buttons for 10 seconds to access LEVEL 4 LEVEL C only visible when COMMS option fitted Set SP1 main temperature set point to 10 C To access the set up menu push and hold UP and DOWN buttons simultaneously for 3 seconds Press and hold UP ...

Страница 8: ... STYLE COOL ONLY Method 1 In LEVEL 3 change the rsEt value to All rsEt All Change the settings in LEVEL 1 through LEVEL 4 to match the settings in the PID STYLE COOL ONLY set up Method 2 In LEVEL 2 change the unit value to nonE unit nonE In LEVEL 3 change the sp1 d value to rLy2 and sp2 d to rLy1 sp1 d rLy2 sp2 d rLy1 Change the settings in LEVEL 1 through LEVEL 3 to match the settings outlined in...

Страница 9: ...ert Ave Chicago IL 60639 U S A APPLIED STANDARDS Application of Council directive Machinery Directive 89 336 EEC Standards to which conformity is declared EN61326 1997 Class A EN61326 1997 Industrial Location Report number J20022721 011 Low voltage directive 73 23 EEC European union EU Standards to which conformity is declared EN61010 1 A1 97 EN61010 2 010 A1 97 Report number J20022721 L01 TESTING...

Страница 10: ...ree of charge to Buyer or credit to buyer the price of the defective products ALL OTHER WARRANTIES EXPRESS OR IMPLIED ARE EXCLUDED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT SHALL TECA BE LIABLE FOR ANY CLAIM BASED UPON BREACH OF EXPRESS OR IMPLIED WARRANTY OR ANY OTHER DAMAGES WHETHER SPECIAL INDIRECT INCIDENTAL CONSEQUE...

Отзывы: