background image

Possible troublesomes on high intensity  part number 113780

To be used in the manual:

figure 3-4 page 23 for the localization of each items inside the power supply of each flash-head

figure 3-6 page 28 for the internal wiring of the power supply of each flash-head 

figure 3-7 page 29 for the internal wiring of the controller

figure 2-1 page 16 for the visual indicators on the command card

Possible troublesomes

Action

Solution

Red power control indicator (

as 

shown in figure 3-6 page 28) 

for 

voltage presence is off 

As per figure 3-6 page 28:

 Check input voltage 230VAC 

between the terminals 1 and 2 on the main terminal 
connection TB1, and the switch position and the status of the 
surge protection. 

Replace the defective part (surge 
protection 

DS215-230/G part 

number 451721 

or switch position) 

if necessary

D15 is off on the command card 

(as 

per figure 2-1 page 16)

230VAC is present but the light does 
not work.

As per figure 3-6 page 28: 

Check the presence of the 48Vdc 

voltage on the 2 outputs of power supplies part number 
113742 and the status of their fuse

Replace the power supply part 
number 113742 or the fuse if 
necessary

The light works permanently on day 
mode, twilight mode or night mode

Check if S1 is on « remote». Or check the wires coming from 
the controller on the terminals 3 and 4 of TB1 to the relay and 
up to the 2 command board part number 113944(HI)L and 
113944(HI)R. 

Put S1 in “test mode”:

When S2 in night mode, the relay 3 must be lighted
When S2 is in day mode, the relay 4 must be lighted
When S2 is in twilight mode, all relays should be off

Tighten the terminals on TB1, on 
the relay. Replace a 48Vdc  relay if 
necessary

Some indicators D6 to D12 are red 
blinking on the command card 

(as 

per figure 2-1 page 16)

One led projector (or more) does not 
work

Tighten the wires of each led projector inside the stainless 
cabinet

Otherwise tighten the green terminals of the 8 power cards 
(total 16 wires “-“) and terminals 1 to4 on TB2 (total 4 wires 
“+”)

Otherwise check the power card and their projector according 
to the 

procedure below*

Replace power card part number 
113741B or projector part number 
113761-4 if necessary

D13 is blinking and D14 is off on the 
command card 

(as per figure 2-1 

page 16)

The flashes of the light is not 
synchronized with the other lights 
and it flashes at 15 pulse per minute

The top sync is not received from the controller.

Check the wires connection from the controller on  terminals 
11 of TB1 

as per figure 3-7 page 29 

to the 2 command cards 

in the  power supply of flash-head on TB1 7 as

 per figure 3-6 

page 28

Replace the command card part 
number 113744L and/or 113744R 
in the power supply of the flash-
head if necessary

The flashes of all lights are not 
synchronized

The top sync of the controller is not send or not received by 
the lights.

Check the wires connection from the controller on  terminal 
11 of TB1 

as per figure 3-7 page 29

, to the power supply of 

each flash-head 

Replace the command card part 
number 113744 in the controller if 
necessary

The light does not send any alarm to 
the controller in case of default

Check the wires connection from the controller on the 
terminal 10 on TB1 a

s per figure 3-7 page 29 

up to the power

supply of the light terminal 6 on TB1 a

s per figure 3-6 page 

28

Check that the light number that has been assigned is unique 
on the fault transmitter card

Replace the fault transmitter card 
part number 113749B if necessary

All lights work in day/twilight/night 
mode permanently

Check the controller is on « remote» position. Otherwise 
check the position of the photocell (in the North in the North 
Hemisphere), the wiring of the photocell and test the photocell
by masking it with your hand

Replace photocell part number 
113135 or the controller if 
necessary

Otherwise call the manufacturer

*: One p

 

 rojector not working

 

 

For example if luminous indicator D7 (or WHITE#2) is red blinking, disconnect the green terminal from its power card and plug it to the 
power card for example D8 (or WHITE#3) close to it. 
- If the luminous indicator D8 does blink also, it means the projector is defective
- If the luminous indicator D8 does not blink, it means the projector is ok but the power card linked to WHITE#2 is defective

1

Содержание OFP-CAB-8E-RW-240-HIA

Страница 1: ...1 OBSTAFLASH HI LED LIGHTING SYSTEM INSTALLATION AND OPERATION GUIDE OBSTA 2 rue Troyon 92316 S vres Cedex FRANCE Phone 33 1 41 23 50 10 Fax 33 1 41 23 50 11 www obsta com January 2021...

Страница 2: ...60Hz 120 230 V 50 60Hz 48 Vdc P N 113782RW 8E 113781L4 113625L 113135 This list is not exhaustive and some options can be added for synchronization and remote alarm control GPS for wireless synchroniz...

Страница 3: ...turn notice authorizes OBSTA to examine and disassemble returned products to the extent OBSTA deems necessary to ascertain the cause of failure The warranties stated herein are exclusive THERE ARE NO...

Страница 4: ...cond one keeps on working in the same azimuth a remote alarm is activated and related luminous indicator goes red The stainless power supply contains 9 modular power cards 2 command cards to monitor t...

Страница 5: ...Power card P N 113741B LED blanche white LED Power card Carte de puissance P N 113741B Up Remote Middle Test mode Down Remote PARAFOUDRE CITEL CITEL SURGE PROTECTION L in e Neu trale 1 2 3 4 5 Nig h...

Страница 6: ...6 Figure 1 2 Outline and mouting dimensions Power supply P N 113782RW 8E...

Страница 7: ...7 Figure 1 3 Outline and mouting dimensions HI flashhead P N 113781L4...

Страница 8: ...1 2 TB1 TB2 TB3 TB4 TB7 TB6 TB5 OUTPUT CONTROLLER LEVELUP 113797AOL 113780 RW 3 N 1 or 4 OUTPUT TRI 380V LEVEL UP 113797AOL INPUT CONTROLLER Intermediary junction box P N 1238DI 113780 RW 3 N 2 or 5...

Страница 9: ...1 WATER RESISTANT LOCK 4 Trous de fixation 9 Passage de cable 11 21 All dim ensionsareinm m 1 SERRURE ETANCHE Mat riel Inox316Lep m in 2m m Material Stainlesssteel thicknessm in 2m m 250 29 BOTTOMVIEW...

Страница 10: ...10 Figure 1 6 Outline and mouting dimensions Photocell Day Twilight Night P N 113135...

Страница 11: ...3625L Fault Transmitter Card Test Night II Test Twlight 0 Test Day I Alimentation d coupage 120 230Vac 48VDC Power Supply COMMAND BOARD 120 230Vac 48VDC II S2 I 0 Carte de commande P N 113744 Command...

Страница 12: ...12 Figure 1 8 Outline and mouting dimensions Controller P N 113625L...

Страница 13: ...10V to 220VAC 50 60Hz Max wattage 1kW 1 3 3 MECHANICAL PROPERTIES Obstaflash Weight 15 kg Dimensions w 158 mm x h 456 mm x l 580 mm Surface Area 870cm Wind Load 35 kg at 240 Km h Power Supply Obstafla...

Страница 14: ...ommand card is switch off during twilight and night mode Second command card P N113744R is used in day twilight and night mode and monitor the power cards of the 2 upper projectors Day command card 11...

Страница 15: ...k at the same frequency If no pulse is received from terminal 3 D14 is off and light flashes on its own at 15 fl per minute as per D13 Warning In case changing master slave dipswitch n 1 position do n...

Страница 16: ...16 Figure 2 1 Luminous indicators on the command card...

Страница 17: ...17 Figure 2 2 Wiring of led circuits on the command card...

Страница 18: ...ediately Pertinent data such as installation drawings schematics interconnection drawings and operation manuals are included in the power supply carton 3 2 Mounting and Preparation 3 2 1 OBSTAFLASH HI...

Страница 19: ...E D bl anche C ar t e de pui ssance LE D bl anche w hi t e LE D P ow er car d C ar t e de pui ssance P N 113741 w hi t e LE D P ow er car d Alimentation d coupage2 120 230Vac 48VDC Power Supply 2 120...

Страница 20: ...ugh 48VDC and contains 2 photocells each returning a 0V or 48Vdc output to indicate day twilight or twilight night to the system First Photocell twilight returns a 0V during day and 48Vdc during twili...

Страница 21: ...i s s a n c e L E D b l a n c h e w h i t e L E D P o w e r c a r d C a r t e d e p u i s s a n c e P N 1 1 3 7 4 1 B w h i t e L E D P o w e r c a r d A l i m ent at i on d coupage 2 120 230Vac 48VDC...

Страница 22: ...30 Vac 48 VDC Power Su ppl y C O M M AN D BO AR D 120 230 Va c 48 VDC P A R A FOU D R E C I TE L C I TE L S U R GE P R OTE C TI ON TB2 TB1 1 2 1 4 O N 1 1 OM C N C 1 2 1 4 O N 1 1 O M C N C 1 2 1 4 O...

Страница 23: ...230Vac 48VDC Al i m ent at i on d coupage 2 w h i t e L E D 120 230Vac 48VDC bas down haut up Pow er Suppl y 2 L E D b l a n c h e C a r t e d e p u i s s a n c e w h i t e L E D P N 1 1 3 7 4 1 B P...

Страница 24: ...TB4 cabinet down cabinet top cabinet down cabinet top Cable N 1 Ph 2 Ph 1 P h 3 N Ph 2 N Ph 3 Ph 1 cabinetin down cabinetin top Cable N 2 Cable N 2 Cable N 1 Ph 1Ph 2 Ph 3 N Ph 1Ph 2 Ph 3 N O CUS 0027...

Страница 25: ...tion In each power supply of the flash fire heads there is an emitter board which must be assigned a unique light number up to 32 corresponding to the light number in the controller The fault transmit...

Страница 26: ...On 19 On On 4 On On 20 On On On 5 On 21 On On 6 On On 22 On On On 7 On On 23 On On On 8 On On On 24 On On On On 9 On 25 On On 10 On On 26 On On On 11 On On 27 On On On 12 On On On 28 On On On On 13 On...

Страница 27: ...button allows 3 positions Up remote position the light is in normal operation Middle the light are forced in day or twilight or night mode according to S2 Down remote position the light is in normal...

Страница 28: ...L ED Ca rte d e p u i ssa n ce L ED b l a n ch e P N 113744HIL wh i te L ED Po we r ca rd L ED b l a n ch e Command board Po we r ca rd wh i te L ED Ca rte d e p u i ssa n ce L ED b l a n ch e L ED b...

Страница 29: ...14C OFH Test Ni ght I I Test Tw l i ght 0 Test Day I Out put J C Out put C N Moni i np NO CO M NC O UT Ni ght Day 48 G ND 48V C el l ul e 48V C el l ul e 3 2 1 Com Nc No Power cont r ol Out put 48v Ma...

Страница 30: ...OFH TB2 TB3 T B7 T B6 TB1 TB4 T B5 Ph2 113682RW 113682RW INPUT 113625L Ph1 Ph3 Ph3 Ph1 INPUT TRI 380V Intermediary junction box P N 1238DI Ph2 N N 113682RW OUTPUT TRI 380V LEVEL UP 113797AOL OUTPUT C...

Страница 31: ...s Frequency of cleaning will depend on the environment to which they are exposed SECTION 5 SPARE PARTS Beacon obstaflash PROJECTOR RW 4L 113761L4 Power supply COMMAND CARD 48VDC JOUR 113744L COMMAND C...

Страница 32: ...e going to the junction boxes of the high intensity lights 1 It contain a test button to force day twilight night mode and remote mode controlled by photocell through relays It allows also to 2 synchr...

Страница 33: ...uto L in e Ne u tra l TB2 TB1 48v 48v 2 1 3 4 PHOT OCELL 500 50 LUX P N 113135 Twilight Night Twilight Night Po we r c o n tro l Com Nc No OFH CTR P N 113625L Te s t Nigh t II Te s t T wligh t 0 Te s...

Страница 34: ...BOARD 120 230Vac 48VDC Alimentation d coupage 120 230Vac 48VDC 8 CITELSURGE PROTECTION 7 1 5 TB1 3 1 TB2 Line PARAFOUDRE CITEL 4 6 10 9 2 Neutral 3 11 2 A 2 A 2 A 2 A 1 A 2 A1 A 1 A 2 A 1 A 1 A 1 A 2...

Страница 35: ...e controller After changing the configuration of S1 or S2 the card has to be reset or switch off and on 2 Indicators D1 and D2 when the card is in transmitter or receiver mode 2 1 In transmitter mode...

Страница 36: ...5 minutes by a fixed signal if the default is permanent that is to say at least one time in the 4 last periods of 5 minutes In absence of default during the last 5 minutes the led s go to off The rece...

Страница 37: ...their projector according to the procedure below Replace power card part number 113741B or projector part number 113761 4 if necessary D13 is blinking and D14 is off on the command card as per figure...