Heat Pump Heating Airflow
COMFORT (default) Heat Pump airflow is varied depend
ing on outdoor temperature to maximize comfort.
EFF 325 Fixed airflow used to achieve specified ratings.
This is nominally 325 CFM/ton, but will vary if a 2stage out
door unit is used.
EFF 350 Fixed airflow used to achieve specified ratings.
This is nominally 350 CFM/ton, but will vary if a 2stage out
door unit is used.
MAXIMUM 400 CFM/ton.
Cooling Airflow
COMFORT (default) cooling airflow is varied depending on
humidity and temperature demands settings. This selection en
ables the full dehumidify and comfort capabilities of the system.
When COMFORT is not selected, the unit will not run reduced
airflows for dehumidification.
EFF 325 fixed airflow used to achieve specified ratings –
no dehumidification airflow reduction. This is nominally 325
CFM/ton, but will vary if a 2stage outdoor unit is used.
EFF 350 fixed airflow used to achieve specified ratings –
no dehumidification airflow reduction. This is nominally 350
CFM/ton, but will vary if a 2stage outdoor unit is used.
Содержание TSTAT0101SC
Страница 12: ...12 616 01 1017 02 2 Press under All Days then press EDIT...
Страница 13: ...13 616 01 1017 02 3 Press PERIOD then use the or to select the period to change...
Страница 27: ...27 616 01 1017 02...
Страница 31: ...31 616 01 1017 02 NOTE The INSTALL SERVICE menu will automatically exit after 60 minutes of no activity...
Страница 38: ...38 616 01 1017 02 Fan on with W An option to turn the fan on with a call for furnace heating ON OFF default...
Страница 67: ...67 616 01 1017 02 Defrost With Furnace Choose whether furnace operates during defrost cycle YES default NO...
Страница 74: ...74 616 01 1017 02...
Страница 81: ...81 616 01 1017 02 EInternational Comfort Products LLC PO Box 128 S Lewisburg TN 37091 USA...