18
616 01 1017 02
mostat cable having more than four wires in the event of a
damaged or broken wire during installation.
Each communicating device in the system has a fourpin
connector. It is recommended that the following color code
be used when wiring each device:
DX+ — Green = Data A
DX- — Yellow = Data B
C — White = 24VAC (Com)
R — Red = 24VAC (Hot)
NOTE:
TERMINAL MARKINGS FOR EACH COMMUNICAT
ING SYSTEM COMPONENT MAY NOT BE IN THE SAME
ORDER. IT IS NOT MANDATORY THAT THE ABOVE COL
OR CODE BE USED, BUT EACH CONNECTOR IN THE
SYSTEM
MUST
BE WIRED CONSISTENTLY.
A separate fourpin connector comes inside packaging and
should be used when connecting to furnace (or fan coil). En
sure connector is inserted properly into circuit board.
1. Turn off all power to equipment.
2. If an existing thermostat or control is being replaced:
a. Remove existing thermostat from wall.
b. Disconnect wires from existing thermostat.
c. Discard or recycle old thermostat.
Содержание TSTAT0101SC
Страница 12: ...12 616 01 1017 02 2 Press under All Days then press EDIT...
Страница 13: ...13 616 01 1017 02 3 Press PERIOD then use the or to select the period to change...
Страница 27: ...27 616 01 1017 02...
Страница 31: ...31 616 01 1017 02 NOTE The INSTALL SERVICE menu will automatically exit after 60 minutes of no activity...
Страница 38: ...38 616 01 1017 02 Fan on with W An option to turn the fan on with a call for furnace heating ON OFF default...
Страница 67: ...67 616 01 1017 02 Defrost With Furnace Choose whether furnace operates during defrost cycle YES default NO...
Страница 74: ...74 616 01 1017 02...
Страница 81: ...81 616 01 1017 02 EInternational Comfort Products LLC PO Box 128 S Lewisburg TN 37091 USA...