13.6 Dimensions
Packing 30 x 30 x 40 cm
Weight 1.2 kgs (excl packing)
Weight 3 kgs (incl packing & mounting materials)
13.7 Alarms
Build-in alarms on parameters and system functioning
Outputs, potential free relay outputs through optional OMC-140-2 module
13.8 In accordance with
DNVGL-CG-0339
EMC Directive 2014/30/EU
LV Directive 2014/35/EU
RoHS-2 Directive 2011/65/EU
EMC: ESD IEC 61000-4-2; Radiated Immunity IEC 61000-4-3; Conducted Immunity IEC 61000-
4-6; Fast Transients IEC 61000-4-4; Surge IEC 61000-4-5
Electrical safety: IEC 61010:2010
NMEA 0183 version 4.10 / IEC 61162-1:2010
IEC 62288:2008 Draft IEC 62288:2012
All relevant IMO resolutions
WMO / ICAO / CAP
13.9 Cable specs remote & relay outputs:
Relay outputs:
Cable length maximum:
30 meter
Cable type AC:
Shielded (single ended)
Cable type DC:
Shielded (twisted pair)
Advised
0.75 mm2
Min
0.75 mm2
Max
2.50 mm2
The relays are for signal use only, no power should be switched.
Use additional external relays for power applications!
Remote input:
Cable length maximum:
30 meter
Cable type:
Shielded (single ended)
Advised:
0.75 mm2
Min:
0.25 mm2
Max:
2.50 mm2
13.10 Compass safe distance
Standard compass safe distance = 0.2m.
Steering, standby and emergency compass safe distance = 0.1m.
Содержание OMC-140
Страница 5: ...OMC 140 Installation Manual Page 5 Page intentionally left blank ...
Страница 31: ...OMC 140 Installation Manual Page 31 Repeat this for the other sensors if any ...
Страница 51: ...OMC 140 Installation Manual Page 51 Observator Proprietary Messages POBSBTD POBSCBE POBSVIS ...
Страница 65: ...OMC 140 Installation Manual Page 65 16 Dimensional drawings ...
Страница 66: ...OMC 140 Installation Manual Page 66 Spacer advised to be used in case of retrofitting into a 144x144 cut out ...
Страница 68: ...OMC 140 Installation Manual Page 68 17 3 Optional Keypad panel cut out ...