13 Specifications
13.1 Inputs/Outputs
2 NMEA0183 inputs
1 NMEA0183 output
Micro USB (programming purposes)
RJ45 LAN connector (Future use)
Display interconnection bus
More I/O possible through the option boards
13.2 TFT touch screen
8,5” Super Wide Viewing Angle 170° LCD with long life and low power LED backlight
Active display area: 184.8 x 110.9 mm
Resolution: WVGA 800x480
The used font (Verdana) is non-italic, sans-serif, optimized for TFT readability
For the wind speed indication in the center, the character height is 10 mm which corresponds to
a nominal viewing distance of 2.85 meters
For the other numeric fields the character height is 7 mm which corresponds to a nominal
viewing distance of 2 meters
13.3 Electrical
100..240 VAC, 50/60 Hz, max 50 VA
9-30V Vdc via Optional DC Power Module
Sensor 1 and 2 power output 15..16.5 Vdc max 1.5 W
Connections, pluggable screw terminals for max 2.5 mm²
13.4 Environmental specifications
Operating temperature
–15⁰C..+55⁰C
Storage temperature
–30⁰C..+80⁰C
Humidity: 10..93 %RH
Vibration: IEC 60068-2-6 test Fc
EMC: IEC 60945; IEC 61326-1
IP rating: IP22 when fully flush mounted (228 x 142mm)
13.5 Dimming possibilities
From 0,5..700 cd/m2
Day and night pallet selectable
Manual by means of ‘slider bar’
Automatic by means of ambient light sensor
Central by means of NMEA DDC input
Содержание OMC-140
Страница 5: ...OMC 140 Installation Manual Page 5 Page intentionally left blank ...
Страница 31: ...OMC 140 Installation Manual Page 31 Repeat this for the other sensors if any ...
Страница 51: ...OMC 140 Installation Manual Page 51 Observator Proprietary Messages POBSBTD POBSCBE POBSVIS ...
Страница 65: ...OMC 140 Installation Manual Page 65 16 Dimensional drawings ...
Страница 66: ...OMC 140 Installation Manual Page 66 Spacer advised to be used in case of retrofitting into a 144x144 cut out ...
Страница 68: ...OMC 140 Installation Manual Page 68 17 3 Optional Keypad panel cut out ...