OMC-140 Installation Manual
Page 27
6.4.4 Enabling parameters without the actual data
If you do want to preconfigure the screen layout without any sensor data, you can enable data messages
via the USB terminal mode:
how to connect and enter the menu (see 8 Terminal Mode Configuration).
Navigate to:
1. Device settings
1. Display intensity
2. Sensor 1
3. Sensor 2
If you already know to which port you will connect select the corresponding sensor port.
Otherwise simply open sensor 1.
Change the status of the required data from ‘Auto’ to ‘On’
Installation Settings Sensor 1:
Watchdog Time
1 Baudrate
(4800)
2 Watchdog
(OFF)
3 MWV Relative
(AUTO)
4 MWV Theoretical
(AUTO)
5 MWD True
(AUTO)
6 GGA GPS Quality (AUTO)
7 VTG GPS Ship Heading (AUTO)
8 HDT/THS Gyro Heading (AUTO)
9 VHW Log Speed
(AUTO)
A XDR Data
(AUTO)
B GMP GPS Data (AUTO)
C GST GPS Data
(AUTO)
D MHU Humidity Data (AUTO)
E MMB Baro Data
(AUTO)
F MTA Air Temp. Data (AUTO)
G MDA Combined Data (AUTO)
H MTW Water Temp. Data (AUTO)
I VIS Visibility Data
(AUTO)
J CME Cloud Data
(AUTO)
K BTD Lightning Data (AUTO)
L DBK Depth Data
(AUTO)
M DPT Depth Data
(AUTO)
N VLW Water Distance (AUTO)
O VBW Water Speed (AUTO)
P ROT Rate Of Turn (AUTO)
Содержание OMC-140
Страница 5: ...OMC 140 Installation Manual Page 5 Page intentionally left blank ...
Страница 31: ...OMC 140 Installation Manual Page 31 Repeat this for the other sensors if any ...
Страница 51: ...OMC 140 Installation Manual Page 51 Observator Proprietary Messages POBSBTD POBSCBE POBSVIS ...
Страница 65: ...OMC 140 Installation Manual Page 65 16 Dimensional drawings ...
Страница 66: ...OMC 140 Installation Manual Page 66 Spacer advised to be used in case of retrofitting into a 144x144 cut out ...
Страница 68: ...OMC 140 Installation Manual Page 68 17 3 Optional Keypad panel cut out ...