background image

   PAGE 3

OBLICA

 | SPECIFICATIONS AND PRODUCT GUIDE

2. SPECIFICATIONS

MODEL

BURNER 
TYPE

INJECTORS

NOMINAL GAS 
CONSUMPTION

INLET 
PRESSURE

MANIFOLD 
PRESSURE

TURNDOWN 
PRESSURE

FLUE SIZE

75 x 65

B45

Marked 650: with 
7x0.950mm orifice

26MJ/h

1.13kPA

0.82kPA

0.23kPA

107/164mm

60 x 80

B45

Marked 650: with 
7x0.950mm orifice

26MJ/h

1.13kPA

0.82kPA

0.23kPA

107/164mm

75

B45

Marked 650: with 
7x0.950mm orifice

26MJ/h

1.13kPA

0.82kPA

0.23kPA

107/164mm

TRAD 90

B45

Marked 650: with 
7x0.950mm orifice

26MJ/h

1.13kPA

0.82kPA

0.23kPA

125/205mm

110 / 110H

B100

Marked 1200: with 
7x1.275mm orifice

37MJ/h

0.69kPA

0.73kPA

0.26kPA

125/205mm

TRAD 110

B100

Marked 1200: with 
7x1.275mm orifice

37MJ/h

0.69kPA

0.73kPA

0.26kPA

125/205mm

130 / 130H

B100

Marked 1200: with 
7x1.275mm orifice

37MJ/h

0.69kPA

0.73kPA

0.26kPA

125/205mm

150 / 150H

B135

Marked 1200: with 
7x1.275mm orifice
Marked 1400: with single 
3.9mm orifice

55MJ/h

1.13kPA

0.61kPA

0.22kPA

125/205mm

170 / 170H

B135

Marked 1200: with 
7x1.275mm orifice
Marked 1400: with single 
3.9mm orifice

55MJ/h

1.13kPA

0.61kPA

0.22kPA

125/205mm

200 / 200H

B160

Marked 800: with 
7x1.05mm orifice
Marked 1400: with single 
3.8mm orifice

52MJ/h

1.13kPA

0.50kPA

0.22kPA

125/205mm

250 / 250H

B160

Marked 800: with 
7x1.05mm orifice
Marked 1400: with single 
3.8mm orific

52MJ/h

1.13kPA

0.50kPA

0.22kPA

125/205mm

Содержание ORTAL 110

Страница 1: ...ORTAL SINGLE SIDED FIREPLACES SPECIFICATIONS PRODUCT GUIDE ...

Страница 2: ...pproved DuraVent flue system as specified Consult the relevant authority to determine the need for a permit prior to starting the installation It is the responsibility of the installer to ensure that this fireplace is installed in compliance with the manufacturer s instructions and all the applicable building codes Contact your local distributor dealer for correct flue and flue termination informa...

Страница 3: ...ith 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm TRAD 110 B100 Marked 1200 with 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm 130 130H B100 Marked 1200 with 7x1 275mm orifice 37MJ h 0 69kPA 0 73kPA 0 26kPA 125 205mm 150 150H B135 Marked 1200 with 7x1 275mm orifice Marked 1400 with single 3 9mm orifice 55MJ h 1 13kPA 0 61kPA 0 22kPA 125 205mm 170 170H B135 Marked 1200 wit...

Страница 4: ...68 130 1368 420 692 1278 x 350 130 H 1368 420 892 1278 x 550 150 1636 420 692 1528 x 350 150 H 1636 420 892 1528 x 550 170 1813 420 692 1528 x 350 170 H 1813 420 892 1528 x 550 200 2076 420 692 1968 x 350 200 H 2076 420 892 1968 x 550 250 2550 420 692 2444 x 400 250 H 2550 420 892 2444 x 550 Note Minimum height off of the floor for all front facing Ortal fireplaces is 210mm Appliance legs must not...

Страница 5: ...0H 254 2683 475 915 TR90 254 1170 689 978 TR110 254 1360 689 1059 CLADDING FOR METAL STUDS external cladding The framing structure must be clad externally with non combustible material and gaps sealed with a non combustible fire proof sealant We recommend the fireplace to be in position and flued prior to cladding OPTION 1 METAL STUDS FRAMING Preferred option The frame must be designed to carry th...

Страница 6: ...60 689 1059 662 CLADDING FOR TIMBER STUDS WITH METAL SECTION external cladding internal cladding OPTION 2 TIMBER STUDS WITH METAL SECTION The frame must be designed to carry the entire weight of the finished wall with no component being supported by the fireplace The framing structure must be clad internally and externally with non combustible material and gaps sealed with a non combustible fire p...

Страница 7: ...T EXHAUST AND AIR INTAKE HOT AIR FLOW HEAT RELEASE AS REVEAL VENTING Convection air outlet A convection air outlet is required for all Ortal fireplaces This allows for heat building up within the fireplace cavity to be released back into the space helping to keep the cavity walls cool It must be located at the top of the fireplace cavity and be placed at a maximum of 150mm below the cavity ceiling...

Страница 8: ...ervices We recommend a minimum size of 200x200mm However access panels are not the only option for servicing the fireplace operation mechanisms A technician may also service the fireplace controls by going through the firebox This procedure requires removing the glass panel s taking out the interior media and lifting the grill burner and bottom side explosion valve of the unit The technician would...

Страница 9: ...PAGE 9 OBLICA SPECIFICATIONS AND PRODUCT GUIDE 7 TV CLEARANCES 305mm MIN 305mm MIN RECESSED INSTALLATION FLUSH INSTALLATION ...

Страница 10: ...TAL DECORATIVE ROOM SEALED GAS APPLIANCES HAVE BEEN TESTED AND APPROVED BY AGA IAPMO R T FOR USE WITH NATURAL GAS NG Australian Standard AS5263 0 2016 Decorative Gas Log and Other Fuel Effect Appliances Patent Pending for screen barrier glass bracket USSN 60 040 074 ...

Отзывы: