background image

P1PVKY / P1PVCDKY 

Installation & Service Instructions 

 

 
 

 

 

030099-347 

pg 14 of 14  

         © Copyright 2007 OASIS Corporation 

 

Remove the front door and the top from the cooler and disconnect the blue tubing that 
connects the bulkhead fitting on the back of the cooler to the plastic tee-piece (disconnect the 
tubing at the tee piece) 

 

Connect the blue tube to the inlet side of the Filter Cleaning Cartridge 

 

Using a 12” length of 

¼

” blue tubing, connect the outlet side of the Filter Cleaning Cartridge 

to the tee-piece 

o

 

If a filter system has been installed in the cooler, then use the Filter Cleaning 
Cartridge to bypass the filter system (i.e.disconnect the tube attached to the inlet to 
the filter system and fit it to the inlet of the Filter Cleaning Cartridge & disconnect 
the tube attached to the outlet to the filter system and fit it to the outlet of the Filter 
Cleaning Cartridge) 

 

Reconnect the cooler to the mains water supply 

 

Allow the reservoir to fill with water (leave for about 5 minutes) and dispense water from both 
the cold and ambient systems  to bleed all air from the system

 

 

Let the cooler stand with cleaning solution in it for 20-30 minutes.   

 

After the 20-30 minutes are up dispense water from both systems for 2 minutes to remove all 
traces of cleaning solution.  

 

Disconnect the cooler from the mains water supply and and remove the Filter Cleaning 
Cartridge 

 

Reconnect the blue tube to the tee-piece (or re-install the filter system) 

 

Reconnect the cooler to the mains water supply 

 

General Cabinetry Cleaning: 

 

It is recommended that the machine is cleaned once per week 

 

Turn off the power at the wall socket and remove the power cord at the rear of the machine. 

 

Wear clean rubber gloves to carry out the cleaning functions. 

 

Remove and clean the drip tray assembly. 

 

Clean all machine surfaces with non-abrasive vending machine cleaner/sanitizer. 

 

Replace the drip tray. 

 

Re-connect the machine and turn on the power and check for correct operation 

 
 
 

THIS APPLIANCE MUST BE EARTHED. 

This appliance is not suitable for unsupervised use by young children or aged and infirm persons. The warranty, 

Underwriter’s Laboratory certification and CE certification for this machine are automatically void if any alteration, 

modification, or combination with any other machine or device is deemed to be the source of any claim. The UL and CE 

certification may be void as the result of any alteration or modification. The manufacturer accepts no liability resulting from 

any alteration, modification, or combination with any other machine or device. 

 

EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE, 

OR AGREEMENT EXPRESSED, IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 

 

OASIS East Sp.z o.o. 

Gutenberga 20 str 

44-164 Gliwice SEZ, Poland 

Tel:   +48 32 332 6501   ;   Fax:  +48 32 332 6500 

www.oasis.ie

 

Содержание P1PVCDKY

Страница 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PVKY P1PVCDKY Contents...

Страница 2: ...ion Cooler Installation General Troubleshooting Guidelines Cleaning and Sanitising Instructions Technical Specification Product Dimensions Height 1 110 mm Width 320 mm Depth 345 mm Net Weight 23 kg Fi...

Страница 3: ...t Cold water temperatures may be adjusted via a slotted screw on the body of the control can be accessed through wires on the condenser Turning this screw in the clockwise direction will make the wate...

Страница 4: ...g The entire internal water circuit and all the components which come in contact with water are food grade NSF WRAS approved Mounting Feet The unit is supplied with 4 mounting feet packed inside the f...

Страница 5: ...n place e That the cooler is clean and dust free 5 Install your filtration system see relevant section in this manual 6 Flush out the water cooler a Connect the water supply to the bulkhead fitting at...

Страница 6: ...g any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Disconnect the cooler from the power supply Remove the top from the unit remove the two screws at...

Страница 7: ...rward Remove the door from the cooler The inlet pipe is now visible on the left hand side of the filter compartment Installing the filter system It is recommended that you use a filter system with pus...

Страница 8: ...e cooler in direct sunlight Do not locate the cooler next to a radiator Do not locate the cooler within or directly adjacent to toilet facilities Do not locate the cooler in constantly damp areas bene...

Страница 9: ...l isolation valves Sanitisation EPDWA guidelines state All coolers must be sanitized before commissioning When a customer signs up to the sanitisation program the cooler should be sanitized every 6 mo...

Страница 10: ...of installation g Level the machine using the adjustable feet 6 Connect the water cooler to a potable mains water supply OASIS recommend the use of an EPDA recognised installation kit that includes a...

Страница 11: ...thermostat setting turn anti clockwise to increase the temperature setting of the cold water Disconnect the power from the unit and allow the the ice inside the cooler to melt Water dispensed from th...

Страница 12: ...y Instructions Isolate the water cooler from the mains water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the mains Dis...

Страница 13: ...0858 407 O RING 13 034507 002 COOLING TANK BASE 14 035023 001 DRAIN TUBE 3 8 ID 15 033970 003 DRAIN VALVE ASSY Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12...

Страница 14: ...ove the Filter Cleaning Cartridge Reconnect the blue tube to the tee piece or re install the filter system Reconnect the cooler to the mains water supply General Cabinetry Cleaning It is recommended t...

Отзывы: