background image

P1PV / P1PVCD Series 

Installation & Service Instructions 

 

 
 

 

 

030099-347 Rev. 2 

pg 5 of 16  

         © Copyright 2007 OASIS Corporation 

Spare Parts: 

 

Tri Palm International supplies spare parts for all of its watercoolers.  For European service, 
please check the OASIS web-site at 

www.oasis.ie

 for full illustrated parts breakdowns that give 

full details of all replacement parts.  For service from the United States, refer to the Tri Palm 
International web-site 

www.tripalmint.com

 

 
Pre-Delivery Inspection: 

 
1.

 

Examine the packaging for signs of damage – report any damage to the carrier. 

 
2.

 

Remove the carton from the cooler – cut the strapping tape and lift the carton from the cooler. Store 
the carton and corner posts for repacking the cooler prior to shipping it to the customer. 

 
3.

 

Remove the shipping bag from the cooler 

 
4.

 

Carry out a general inspection of the cooler, ensuring that : 
a)

 

There are no marks or physical damage to the cooler 

b)

 

All accessories are present 

c)

 

All wires and electrical connections are in place at the back of the cooler 

d)

 

All tubes and water connections are in place 

e)

 

That the cooler is clean and dust free 

 
5.

 

Install your filtration system (see relevant section in this manual) 

 
6.

 

Flush out the water cooler 

a)

 

Connect the water supply to the bulkhead fitting at the rear of the unit 

b)

 

Make sure the hot tank switch is off, if applicable, then connect the unit to a power supply 

c)

 

Caution: The unit is now live and suitable safety precautions should be taken 

d)

 

For models with hot tanks, the two buttons on the front left of the cooler face must be pressed at 
the same time to dispense hot water.  Press the dispensing button for hot water and keep the 
button depressed until the water from the outlet runs clear – note that it will take some time to 
bleed all of the air from the hot tank. 

 

  

  

 

 
 

e)

 

If your model is a Cook N’ Cold model, press and keep the button depressed for ambient 
temperature water until the water from the outlet runs clear.  

Содержание P1PV Series

Страница 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PV P1PVCD Series Coolers...

Страница 2: ...th 345 mm 13 6 in Net Weight 23 kg 51 lbs Filter Compartment Height 560 mm 22 in Width 260 mm 10 2 in Depth 120 mm 4 7 in Electrical Specification P1PVKY P1PVK P1PVHSY P1PVHS P1PVHSKY P1PVHSK P1PVCDKY...

Страница 3: ...he water colder and vice versa Ambient Water Circuit The water in the ambient water circuit is not cooled the temperature of the water will be the same as the temperature of the water that comes out o...

Страница 4: ...to NSF standards 51 and 61 The machine is connected to the water supply by a female bulkhead fitting The entire internal water circuit and all the components which come in contact with water are food...

Страница 5: ...no marks or physical damage to the cooler b All accessories are present c All wires and electrical connections are in place at the back of the cooler d All tubes and water connections are in place e...

Страница 6: ...ooler 9 The cooler is now ready for transportation to the customer s premises NOTE Whenever you transport the cooler to or from your premises you should ensure that a shipping bag is placed over the c...

Страница 7: ...valve prior to opening it The container needs to have a minimum capacity of 2 litres 2 quarts Re assemble the cooler by following the above instructions in the reverse order Filter Installation The P1...

Страница 8: ...followed when installing an OASIS water cooler onto an existing mains water system It is recommended that all companies undertake the necessary EPDWA training courses to help maintain the professiona...

Страница 9: ...here they may occur Each cooler should have an independent isolating valve This is intended so that the cooler can be replaced without draining long lengths of piping EUROPE ONLY In accordance with EP...

Страница 10: ...damage to the cooler b That all accessories are present c That all the wires and electrical connections are in place at the back of the cooler d That the cooler is clean and dust free e Sit the machin...

Страница 11: ...off valve in the filter system is in the Open position Water flows from the ambient or hot system no water flows from cold system o Water within cooling system is frozen Check the thermostat setting t...

Страница 12: ...afety Instructions Isolate the water cooler from the water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the water suppl...

Страница 13: ...20 034734 002 034734 002 TUBING 3 8 OUTLET VENT Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12 length of OD plastic tubing Preparation of Filter Cleaning Ca...

Страница 14: ...rd at the rear of the machine Wear clean rubber gloves to carry out the cleaning functions Remove and clean the drip tray assembly Wipe down all machine surfaces with a mild soap solution or mild clea...

Страница 15: ...OASIS Corporation Disconnect the blue tube running from the solenoid to the hot tank inlet see figure for location of this tube Thread the blue tubing through the hole in the shelf as shown above as s...

Страница 16: ...cooler to the mains supply Drain at least 5 litres of hot water from the outlet before switching on the hot tank THIS APPLIANCE MUST BE EARTHED This appliance is not suitable for unsupervised use by y...