background image

P1PV / P1PVCD Series 

Installation & Service Instructions 

 

 
 

 

 

030099-347 Rev. 2 

pg 16 of 16  

         © Copyright 2007 OASIS Corporation 

 

Allow this water to empty into an open bucket 

 

Remove the hot tank from the cooler as follows: 

o

 

Disconnect earth wire from column support 

o

 

Disconnect live & neutral wires from hot tank switch and heat limiter 

o

 

Disconnect vent pipe from front panel 

o

 

Disconnect outlet pipe from water outlet assembly 

o

 

Support the tank while removing the two screws attaching the tank to the shelf 

o

 

Withdraw the tank from the column support 

 

Temporarily plug the vent and hot tank outlet 

 

Prepare a descaling solution by mixing 125 grams of citric acid crystals with one litre of very 
hot water.  (Wearing rubber gloves is recommended )

 

 

Turn the hot tank upside down and pour the descaling solution into the hot tank inlet tube 
using a funnel

 

 

 

Let the unit stand for at least twenty minutes.

 

 

Drain the descaling solution through the hot tank inlet tube

 

 

Replace the hot tank and rebuild the cooler

 

 

Reconnect the cooler to the mains supply

 

 

Drain at least 5 litres of hot  water from the outlet before switching on the hot tank

 

 
 
 
 

THIS APPLIANCE MUST BE EARTHED. 

This appliance is not suitable for unsupervised use by young children or aged and infirm persons. The warranty, 

Underwriter’s Laboratory certification and CE certification for this machine are automatically void if any alteration, 

modification, or combination with any other machine or device is deemed to be the source of any claim. The UL and CE 

certification may be void as the result of any alteration or modification. The manufacturer accepts no liability resulting from 

any alteration, modification, or combination with any other machine or device. 

 

EXCEPT AS SET FORTH HEREIN, THE MANUFACTURER MAKES NO OTHER WARRANTY, GUARANTEE, 

OR AGREEMENT EXPRESSED, IMPLIED OR STATUTORY, INCLUDING ANY IMPLIED WARRANTY OR 

MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 

 

Manufacturing location: 

Europe 

 

OASIS East Sp.z o.o. 

Gutenberga 20 str 

44-164 Gliwice SEZ, Poland 

Tel:   +48 32 332 6501   ;   Fax:  +48 32 332 6500 

www.oasis.ie

 

 
 

In North America, contact: 

 

TRI PALM INTERNATIONAL, LLC 

222 East Campus View Blvd. • Columbus, OH  43235 U.S.A. 

1-800-64-OASIS (1-800-646-2747) 

www.oasiswatercoolers.com

 

 

 

Содержание P1PV Series

Страница 1: ...INSTALLATION SERVICE INSTRUCTIONS P1PV P1PVCD Series Coolers...

Страница 2: ...th 345 mm 13 6 in Net Weight 23 kg 51 lbs Filter Compartment Height 560 mm 22 in Width 260 mm 10 2 in Depth 120 mm 4 7 in Electrical Specification P1PVKY P1PVK P1PVHSY P1PVHS P1PVHSKY P1PVHSK P1PVCDKY...

Страница 3: ...he water colder and vice versa Ambient Water Circuit The water in the ambient water circuit is not cooled the temperature of the water will be the same as the temperature of the water that comes out o...

Страница 4: ...to NSF standards 51 and 61 The machine is connected to the water supply by a female bulkhead fitting The entire internal water circuit and all the components which come in contact with water are food...

Страница 5: ...no marks or physical damage to the cooler b All accessories are present c All wires and electrical connections are in place at the back of the cooler d All tubes and water connections are in place e...

Страница 6: ...ooler 9 The cooler is now ready for transportation to the customer s premises NOTE Whenever you transport the cooler to or from your premises you should ensure that a shipping bag is placed over the c...

Страница 7: ...valve prior to opening it The container needs to have a minimum capacity of 2 litres 2 quarts Re assemble the cooler by following the above instructions in the reverse order Filter Installation The P1...

Страница 8: ...followed when installing an OASIS water cooler onto an existing mains water system It is recommended that all companies undertake the necessary EPDWA training courses to help maintain the professiona...

Страница 9: ...here they may occur Each cooler should have an independent isolating valve This is intended so that the cooler can be replaced without draining long lengths of piping EUROPE ONLY In accordance with EP...

Страница 10: ...damage to the cooler b That all accessories are present c That all the wires and electrical connections are in place at the back of the cooler d That the cooler is clean and dust free e Sit the machin...

Страница 11: ...off valve in the filter system is in the Open position Water flows from the ambient or hot system no water flows from cold system o Water within cooling system is frozen Check the thermostat setting t...

Страница 12: ...afety Instructions Isolate the water cooler from the water supply this may be done by closing any shut off valve fitted to the installation or temporarily disconnecting the cooler from the water suppl...

Страница 13: ...20 034734 002 034734 002 TUBING 3 8 OUTLET VENT Equipment Household bleach 5 sodium hypochlorite Mild soap solution Plastic bucket One 12 length of OD plastic tubing Preparation of Filter Cleaning Ca...

Страница 14: ...rd at the rear of the machine Wear clean rubber gloves to carry out the cleaning functions Remove and clean the drip tray assembly Wipe down all machine surfaces with a mild soap solution or mild clea...

Страница 15: ...OASIS Corporation Disconnect the blue tube running from the solenoid to the hot tank inlet see figure for location of this tube Thread the blue tubing through the hole in the shelf as shown above as s...

Страница 16: ...cooler to the mains supply Drain at least 5 litres of hot water from the outlet before switching on the hot tank THIS APPLIANCE MUST BE EARTHED This appliance is not suitable for unsupervised use by y...

Отзывы: