P1PV / P1PVCD Series
Installation & Service Instructions
030099-347 Rev. 2
pg 3 of 16
© Copyright 2007 OASIS Corporation
General Information:
•
The P1PV & P1PVCD Series coolers are designed for connection to a supply of potable water.
The cooler should not be connected to water supplies of unknown bacterial quality or those that
are not already fit for human consumption. The machine should only be connected to a potable
drinking water supply.
•
This unit is suitable for indoor use in domestic, commercial & industrial locations. They should
not be sited in locations where they may be subjected to rain or snow.
Cooling System:
•
The P1PV & P1PVCD Series coolers use the OASIS Pressure Vessel Direct Chill (PVDC)
cooling tank system. The cooling tank is manufactured from 304 Stainless Steel which is non-
corrosive and inert.
•
The cold water temperature is preset at the factory at approximately 7°C (45°F) – the water
temperature is controlled by a thermostat that is located on the back of the unit. Cold water
temperatures may be adjusted via a slotted screw on the body of the control (can be accessed
through the hole in the metal panel in the filter compartment). Turning this screw in the
clockwise direction will make the water colder (and vice versa).
Ambient Water Circuit:
•
The water in the ambient water circuit is not cooled - the temperature of the water will be the
same as the temperature of the water that comes out of the building water supply and the
ambient room temperature. The ambient water should be flushed after long periods of non use.
Hot Water System:
•
The P1PV & P1PVCD Series coolers use a two-piece hot tank to aid in cleaning out scale. The
hot tank is manufactured from 304 Stainless Steel which is non-corrosive and inert.
•
The hot water temperature is preset at the factory at approximately 88°C (190°F) – the water
temperature is controlled by a thermostat that is located on the hot tank. Hot water temperatures
may be adjusted via a slotted screw on the body of the control (can be accessed through the hole
in the metal panel in the filter compartment). Turning this screw in the clockwise direction will
make the water hotter (and vice versa).
Compressor:
•
The compressor uses the hydrofluorocarbon refrigerant R134a which is a non-Ozone depleting
substance with a Global Warming Potential of 1,300. The
compressor is controlled by an electromechanical thermostat
that controls the temperature of the water in the direct chill
unit.
Cup Dispenser:
•
The P1PVCD Series contains an integrated cup dispenser built
into the top of the cooler. This is the only difference between
the P1PV Series and the P1PVCD Series.