background image

6.  APPENDIX

34

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

80900073

72200077

20000-220068

20000-220245

301030-00000006

80700215

80200018

82500006

80700705

80600042

80700218

80702344

80900055

80702345

80701502

20000-360157

20000-140150

2001-3605

83000068

2000-1460

81000011

304030-00000002

20000-140178

2004-1437

32009-220029

80700704

32012-120061

80701849

20000-110448

72200136

20000-360297

2000-3928

82600008

Front frame

CM404

Waterproof box

Plastic fan net

Axial fan blades

Median septum

Dc motor

Reactor

After the network

Finned heat exchanger

Motor bracket

Fan chamber ceiling

Top

Press chamber top plate

Electrical box support plate

Pressure switch

Needle valve

Pressure switch

Water flow switch

There-way valve

Electronic expansion valve

There-way valve

Filter

Four-way valve

Junction box body

Right side of the plate

Titanium tube heat exchanger

Chassis

Compressor

Variable frequency controller

Relay

3-position terminal block

Switching power supply

ABS

882400072

abs

Φ

461 ABS+30%GF

Φ

405

×

134-

Φ

8(7)

×

3

Galvanized plate

ZWS40-E51

R1650FNKZ 16A 50Hz 5mH

Galvanized plate

650

×

245

×

550

×Φ

7

×

1.5 1.8

Galvanized plate

Galvanized plate

ABS

Galvanized plate

Galvanized plate

0.30MPa/0.15MPa 

±

0.05 NO

40mm 1/2"

3.2MPa/4.4MPa 

±

0.15 NC

PSL-1 3/4

Φ

6.5-2

×Φ

6.5(T)

×

0.75 T2M

DPF(B)1.65C-007

Φ

9.52-2

×Φ

6.35(T)

×

1.0

Φ

9.7-

Φ

9.7(

Φ

19) T2M

SHF-9H-35U-P/C03C01S

ABS

Galvanized plate

Φ

9.52

×

6m 

Φ

110

Galvanized plate

SVB140FCAMC

882400120

HATF903AS30AC220 AC220V 30A

RS9101(450V~ 4mm2 )(L

N

PE)

EPS-15-12

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

1

1

2

1

1

2

1

1

1

1

1

1

1

1

1

1

33

6.  APPENDIX

6.3  Explosive view of the unit

Moddel:Oasis I9

Complete machine structure explosion diagram

Electrical control structure explosion diagram

Содержание I19

Страница 1: ...SWIMMING POOL HEAT PUMP UNIT Installation Instruction Manual...

Страница 2: ......

Страница 3: ...ch 4 5 4 6 4 7 Silent 4 8 4 9 4 10 4 11 Main board 5 Maintenance and Inspection 6 Appendix Installation illustration Swimming Pool Heat Pumps Location Parameter list and breakdown table Cable specific...

Страница 4: ...mming pool water and keeps the temperature constant For split type unit The indoor unit can be Discretely hidden or semi hidden to suit a luxury house Our heat pump has following characteristics 1 Dur...

Страница 5: ...The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Applia...

Страница 6: ...eparately from domestic waste must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance 6 Directive 2002 95 EC RoHs T...

Страница 7: ...oise Water Connection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net Weight Shipping Weight Nominal Heating Capacity kW Btu h kW Btu h kW kW A A W R...

Страница 8: ...antity Compressor Fan Quantity Fan Power Input Fan Rotate Speed Fan Direction Noise Water Connection Water Flow Volume Water Pressure Drop max Unit Net Dimensions L W H Unit Ship Dimensions L W H Net...

Страница 9: ...2 2 The dimensions for Swimming Pool Heat Pump Unit Modles Oasis I9 Oasis I12 unit mm 2 SPECIFICATION 6 545 956 1000 398...

Страница 10: ...2 2 The dimensions for Swimming Pool Heat Pump Unit Models Oasis I19 unit mm 2 SPECIFICATION 7 Water inlet 40 Water outlet 40 96 790 490 862 466 1115 1160 467...

Страница 11: ...teps when using for the first time 1 Open valve and charge water 2 Make sure that the pump and the water in pipe have been filled with water 3 Close the valve and start the unit ATTN It is necessary t...

Страница 12: ...us source of fresh air which reduces it efficiency and may prevent adequate heat delivery 3 2 Swimming Pool Heat Pumps Location Normally the pool heat pump is installed within 7 5 metres of the pool T...

Страница 13: ...o the basepan and drain out through the barbed plastic condensation drain fitting on the side of the basepan This fitting is designed to accept 20mm clear vinyl tubing which can be pushed on by hand a...

Страница 14: ...our pool pump is running when the pool temperature drops more than 0 2 below set temperature Time Delay The unit is equipped with a 3 minute built in solid state restart delay included to protect cont...

Страница 15: ...ed to enter and exit the mute mode with one click 4 2 Key and icon function instruction Key symbols It is used to switch the unit mode temperature setting and parameter setting It is used to carry out...

Страница 16: ...the unit It will display when compressor is started It will display when water pump is started It will display when fan is started When the timing mute function is started it keeps bright for a long...

Страница 17: ...shut down the wire controller will display as follows Operations are the same as under ON OFF main interface 4 4 Mode switch Under the main interface Short press to switch the unit among heating cooli...

Страница 18: ...When the unit is under the defrosting state the defrosting symbol is on with the display interface as follows Notes 1 After completing the defrosting the unit will be automatically switched to the hea...

Страница 19: ...erating steps the changes will not be saved and return to the main interface Under the clock setting interface Long press for 2 s to enter into the system times setting interface Short press Press or...

Страница 20: ...interface Notes 1 Under the Timer ON OFF setting interface if there is no operation for 20 s the system will automatically memorize user s settings and return to the main interface 2 Under the Timer O...

Страница 21: ...p long press of for 2 s Short press or Short press for entering the hour digit setting of timing on silent Short press or Short press for confirming the timing on silent and turn to the setting of tim...

Страница 22: ...nd the screen will be lighten after other operations conducted 2 Under the OFF interface locking operation is available and the operation method is the same as locking screen under the ON interface 2...

Страница 23: ...sor Check the pressure switch and cold circuit Check or change the temp Sensor Check the pressure switch and cold circuit check and replace this temp sensor Check whether fan motor is broken or locked...

Страница 24: ...nt Check the input voltage measurement Check the input voltage measurement Check and adjust the current measurement Check the communication connection Check the PFC switch tube short circuit or not Ch...

Страница 25: ...n Instruction 10 2 Parameter list Meaning 28 28 27 Remarks Adjustable Adjustable Adjustable Default Refrigeration target temperature set point Heating the target temperature set point Automatic target...

Страница 26: ...23 Controller interface diagram and definition 4 11 Main board Oasis I9 I12 4 Use and Operation Instruction 1 2 3 1 2 1 2 A B 1 2 1 2 4 5 6 3 1 2 4 5 6 3 1 2 1 2 1 2 4 5 6 3 7 8 9 1 2 ACN1 ACL1...

Страница 27: ...1 2 3 1 2 1 2 A B 1 2 1 2 4 5 6 3 1 2 4 5 6 3 1 2 1 2 1 2 4 5 6 3 7 8 9 Controller interface diagram and definition 4 11 Main board Oasis I19 24 4 Use and Operation Instruction 1 2...

Страница 28: ...put Water output temperature input System fan coil temperature input Ambient temperature input System Exhaust temperature input Earth wire Earth wire System suction temperature input Water input tempe...

Страница 29: ...Work procedure Work shall be undertaken under a controlled procedure so as to minimise the risk of a flammable gas or vapour being present while the work is being performed Work procedure Work shall b...

Страница 30: ...times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufacturer s technical department for assistance The following checks shall be applied to instal...

Страница 31: ...sphere from a leak Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also take into a...

Страница 32: ...e that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylin...

Страница 33: ...le before the task is commenced a Become familiar with the equipment and its operation b Isolate system electrically c Before attempting the procedure ensure that Mechanical handling equipment is avai...

Страница 34: ...line MCB Creepage protector Signal line 2 n 0 5mm Nameplate maximum current Earth line No more than 10A 20A 32A 40A 40A 63A 80A 100A 125A 160A 225A 250A 280A 2 1 5mm 2 2 5mm 2 4mm 2 6mm 2 10mm 2 16mm...

Страница 35: ...emperature R410A Pressure MPa Temperature R32 Temperature R410A Temperature R32 0 0 3 0 5 0 8 1 1 3 1 5 1 8 2 2 3 2 5 2 8 3 3 3 3 5 3 8 4 4 5 5 5 5 51 3 20 9 4 11 19 24 31 35 39 52 5 20 9 3 5 10 18 23...

Страница 36: ...33 6 APPENDIX 6 3 Explosive view of the unit Moddel Oasis I9 Complete machine structure explosion diagram Electrical control structure explosion diagram...

Страница 37: ...e switch Needle valve Pressure switch Water flow switch There way valve Electronic expansion valve There way valve Filter Four way valve Junction box body Right side of the plate Titanium tube heat ex...

Страница 38: ...35 6 APPENDIX 6 3 Explosive view of the unit Moddel Oasis I12 Complete machine structure explosion diagram Electrical control structure explosion diagram...

Страница 39: ...re switch Needle valve Pressure switch Water flow switch There way valve Electronic expansion valve There way valve Filter Four way valve Junction box body Right side of the plate Titanium tube heat e...

Страница 40: ...6 APPENDIX 6 3 Explosive view of the unit 37 Moddel Oasis I19 Complete machine structure explosion diagram Electrical control structure explosion diagram...

Страница 41: ...Needle valve Pressure switch Water flow switch There way valve Electronic expansion valve There way valve Filter Four way valve Junction box body Right side of the plate Titanium tube heat exchanger...

Страница 42: ...Note...

Страница 43: ......

Страница 44: ...Code 20190508 0001...

Отзывы: