Oasis SmartChem - INSTALLATION AND OPERATION MANUAL
Page
5
of
22
DO NOT CONNECT POWER TO THE
OASIS SMARTCHEM
UNTIL ALL THE
FOLLOWING CRITERIA HAS BEEN MET.
•
Take a sample of your pool water to a pool shop, have it tested and have balanced your pool to
the appropriate ranges as specified on pg1.
o
Always take a sample of your pool water away from the return jets to ensure an accurate
reading.
•
It is highly recommended that before you install the
Oasis SmartChem
system, that you sit the
probe/s in your pool water for 24hrs. This will help the probes to give a more accurate reading
from the time of installation and will help with the longevity of the probes.
DO NOT CUT ANY PIPEWORK TO FIT THE MANIFOLDS BEFORE TURNING ANY
FILTRATION, CLEANING, CIRCULATION OR HEATING PUMPS OFF.
You will need to leave them off for a period of time to ensure the glue used to connect the
manifolds has had the appropriate time to dry and bond properly to achieve correct pressure
rating.
The Sensor & Injection Manifolds suit 50mm pipe, 4 reducing bushes will be required if you are installing
the manifolds into 40mm pipe.
•
The pH and ORP probes and the appropriate Sensor Manifold have been installed into the
pipework (see the diagram below).
o
The pH and ORP probes will be inserted into small bottles of solution. It is advised that
you keep these bottles (after rinsing them out) for long term storage capability of the
probes if necessary.
•
The pH and ORP probes have been plugged into the
Oasis SmartChem
controller. (see diagram
below)
•
The communication cable from the
Oasis SmartChem
has been connected to either the Oasis
Smart Master Controller or the right-hand port in the last Expansion Unit. (see diagram below)
WATER FLOW
Install the probes into the
coupling like this,
it will help the probes
give a more accurate
reading.
Not like this
Содержание SmartChem
Страница 1: ......
Страница 19: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 18 of 22...
Страница 24: ...Oasis SmartChem INSTALLATION AND OPERATION MANUAL Page 23 of 22 9 NOTES...