5
- English -
Installation
Place the unit at a flood protected position at a distance from the pond edge of at least 6.6 ft (2 m) on a firm and level
ground. As an alternative, the filter can be burried up to the recess in the container. Maximum height difference be-
tween filter lid and outlet point: max. 6.6 ft (2 m) (14). Do not expose the unit to direct sun radiation. Ensure unre-
stricted access to the cover to be able to carry out work on the unit.
Installation
Fitting hose connections
The max. pump head height is 7.25 psi (0.5 bar). Only operate the unit with pressure hoses which are approved at
least for 2.9 psi (0.2 bar) or the maximum pump pressure. Saw off the stepped hose nozzle at the appropriate point of
the corresponding hoses (13). Push or screw the hoses onto the stepped hose nozzle and secure with a hose clip.
Installation at the water inlet
Push the union nut over the black stepped hose nozzle, fit the hose, insert the flat sealing ring in the union nut, and
screw onto the water inlet socket.
Installation at the water outlet
Push the union nut over the transparent stepped hose nozzle, fit the hose, insert the green flow indicator flag into the
union nut, and screw onto the water outlet socket.
Installation at the cleaning connection
To permanently fit a drain hose to the cleaning connection, unscrew the cover cap from the cleaning connection, push
the union nut over the transparent hose nozzle, fit the hose, insert the green flow indicator flap into the union nut, and
firmly tighten it on the cleaning connection. During filter operation, ensure that the cleaning connection or a drain hose
connected to it is always closed with the cover cap and the inserted flat sealing ring as a security measure, should the
function switch be unintentionally set to „Cleaning". To close the drain hose with the cover cap, push or turn the black
stepped hose nozzle with its thread onto the hose and secure with the hose clip, firmly screw tighten with the flat
sealing ring inserted.
Start-up
Attention! Ultra-violet radiation.
Possible consequences:
Eye or skin injury from burns.
Protective measures:
−
Never operate the UVC lamp outside its housing.
−
Never operate the UVC lamp in a housing that is defective.
Attention! Breakable glass.
Possible consequences:
Injury of your hands caused by cuts.
Protective measures:
Handle both quartz glass and UVC lamp with care.
Attention!
Never operate the unit with a water pressure of more than 2.9 psi (0.2 bar)!
Attention!
Never operate the unit without water or without pump strainer casing!
This is how to connect the power supply:
Switching on:
Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off:
Disconnect the power plug.
Adhere to the safety information given above! Always switch the pump on prior to starting the unit, and check the
correct seating of the connected hoses, the cover cap and the clamping ring with safety latch. The function switch must
be turned to the „Filter“ symbol. Connect the power supply, the blue control lamp is lit. Note: After a new installation,
the unit only reaches its full biological cleaning effect after a few weeks. The full effect on bacteria is only reached as
from an operating temperature of 50°F (+ 10°C).
Note: In the event of overheating, the installed temperature monitor switches the UVC lamp off automatically, the lamp
automatically switches on again once cooled down.
Содержание FILTOCLEAR 1.600
Страница 1: ...FiltoClear 1600 3000 4000 02 H GAW_Filtoclear_end_ 27 02 12 12 41 Seite 2...
Страница 3: ...3...
Страница 13: ...13...
Страница 14: ...14...
Страница 15: ......
Страница 16: ...OASE North America Inc www oase livingwater com 19683 03H...