- EN -
58
7
Remedy of faults
Malfunction
Possible cause
Remedy
No flow of water
Filter pump not switched on
Switch on the filter pump, connect the power plug
Supply to filter system or return to pond
blocked
Clean the supply and/or return
Water flow insufficient
Bottom drain, pipe or hose blocked
Clean, replace if necessary
Hose kinked
Check hose, and replace if necessary
Excessive loss in lines
Reduce line length to necessary minimum
Water remains cloudy
Insufficient pump capacity
Adjust the pump capacity accordingly
−
For AquaMax Eco Premium 12000, 16000,
20000, switch off the SFC (Seasonal Flow
Control). SFC reduces the quantity of water by
up to 50 %.
The water is extremely soiled.
−
Remove algae and leaves from the pond.
−
If the water is particularly contaminated,
change 30 % of the water to avoid damage to
the fish.
Dirt particles do not reach the drum filter
module.
−
Optimise the water flow so that the skimmer
and/or the filter pump can draw in the dirt
particles.
−
Align the skimmer and/or filter pump in relation
to the water flow so that they can draw in dirt
particles.
Too many pond animals
Reduce number of pond animals
Screen elements clogged or damaged
Clean or replace screen elements
Drum seal incorrectly positioned
Check the seating of the drum seal
Drum seal is damaged
Replace the drum seal
Foam filters soiled
Clean the foam filters
Unusual noises in the drum Large dirt particles have collected in the filter
drum
Remove a screen element and remove dirt
particles from the filter drum
Rinsing channel blocked
Large particles of dirt such as string algae
are blocking the dirt channel
Remove a screen element and clean the dirt
channel
Filter drum is partially
soiled, cannot be cleaned
Rinsing nozzle clogged
Clean the rinsing nozzle, replace if necessary
Water is flowing via the
emergency overflow
Screen elements clogged
Clean/descale the screen elements
Pump capacity too high
Reduce the pump capacity
The pipe of the dirt outlet is blocked
Clean the pipe
Time-dependent cleaning
function (interval) does not
start
The control system checks the function of the
level detection device.
−
This check is started automatically if too
few automatic cleaning procedures have
been carried out.
−
Wait. The check takes a maximum of 24 hours.
−
The check is completed once the level
detection function is triggered. An automatic
cleaning procedure is carried out.
−
If the level detection device is not triggered
within 24 hours,
Er22
is displayed. The time-
dependent cleaning cycle is activated.
(
→
System messages)
No display on the control
system
Cable not connected
Check cable connection
Control system has switched off due to
overheating (temperature switch)
Protect the control system from heat and allow it to
cool down
−
The control system will switch back on
automatically when it has cooled down
−
Error message
Er66
gives a warning before the
control system overheats
Safety fuse has tripped due to a blockage of
the rinsing pump (excessive current
consumption)
Clean the rinsing pump (
→
Cleaning/removing the
rinsing pump)
−
Replace the fuse (
N)
−
Only use 5 × 20 mm, 8 A slow-blow / 250 V
safety fuse.
Содержание BioTec Premium 80000 EGC
Страница 2: ...2 A BTC0089...
Страница 3: ...3 B BTC0032...
Страница 4: ...4 C BTC0091 D BTC0027...
Страница 5: ...5 E F BTC0022 BTC0019 G ProfiClear0040 H FMR0031...
Страница 6: ...6 I EGC0003 J ProfiClear0047 K L BTC0031 BTC0026...
Страница 7: ...7 M BTC0090 N BTC0020...
Страница 8: ...8 O BTC0021 P BTC0025...
Страница 9: ...9 Q BTC0028 R BTC0029 S T BTC0023 BTC0024...
Страница 290: ...RU 290 RU 8 30 12 30...
Страница 292: ...RU 292 8 4 313 8 5 313 8 6 314 8 6 1 314 8 6 2 314 8 7 314 8 8 315 8 9 315 9 316 10 316 11 316 12 316 13 317 318...
Страница 293: ...RU 293 1 OASE Living Water BioTec Premium 80000 EGC 1 1 1 1 1 1 1 2 2 2 1...
Страница 294: ...RU 294 2 2 ICD 20 2 3 3 3 1 BioTec Premium 80000 EGC 4 C 35 C...
Страница 297: ...RU 297 4 B 4 1 UAC 12 oder UDC 30 UAC 12 UDC 30 2 UAC 12 UDC 30 2 25...
Страница 298: ...RU 298 5 500 500 ProfiClear Classic 110 4 2 4 2 1 45 50 4 2 2 50 2 38 1 5 12500 C 1 2 50 2 38 1 5 3 50 2 4 90 2...
Страница 301: ...RU 301 5 OASE PondoVac 24 5 1 A 1 2 3 4 5 6 7 8 9...
Страница 302: ...RU 302 3 4 10 C 36 5 2 1 9000 2 9000 K 1 2 5 3 Er77 Er77 12 E7 Er77 Er77...
Страница 303: ...RU 303 M 1 Er11 2 3 4 5 6 5 12500 4 100 3 1 75 2 50 1 25 1...
Страница 305: ...RU 305 6 3 20 In Cleaning CL Cleaning 6 4 3 6 CL 6 5 6 5 1 CL Cleaning 10 7 8 1 Cl 10 2 5 5 3 10 30 1 30 10 5...
Страница 306: ...RU 306 6 5 2 EC Extra Cleaning 20 1 EC 10 2 5 5 3 10 60 1 60 10 5 6 5 3 In 20 0 1 In 10 2 5 5 3 0 3 60 0 1 60 0 5...
Страница 308: ...RU 308 6 8 4 Er11 Er22 12 C 24 5 24 Er33 20 5...
Страница 309: ...RU 309 Er44 3 5 OASE 27872 5 Er55 960 48 5 960 Er66 Er77...
Страница 310: ...RU 310 7 AquaMax Eco Premium 12000 16000 20000 SFC Seasonal Flow Control SFC 50 30 24 24 Er22 Er66...
Страница 311: ...RU 311 N 5 20 8 250 OASE Biokick 2 1...
Страница 312: ...RU 312 8 8 1 PumpClean OASE 8 2 DN 75 10 8 3 100 10 N 1 5 6 2 DN 75...
Страница 313: ...RU 313 3 DN 75 4 5 25 8 4 DN 75 O 1 2 3 4 5 6 7 8 8 5 L 1 2 3...
Страница 314: ...RU 314 8 6 8 6 1 P 1 180 2 3 4 5 6 7 180 8 6 2 Er33 Er55 Oase PumpClean OASE 1 2 3 4 8 7 Q 1 2 SW 5 3 4 5 6 7...
Страница 315: ...RU 315 R 1 2 8 8 S 1 2 8 9 T 1 2 3 4...
Страница 316: ...RU 316 9 4 C 20 10 C 4 C 8 10 OASE 11 OASE www oase livingwater com zapasnyechasti di 12...
Страница 319: ...319...
Страница 320: ...54882 10 17...