23. Instruction
Setting
23.1 Functions:
►
Calibration (Press Cal Key for 3 Seconds):
Select the calibration routine pH or Redox by Up or Down key.
Standard Routine calibration pH probe is 7 and 4 buffer solution and Redox 465 mV buffer solution
►
Set Point (Press Set Key for 3 Seconds)
Press Set Key and choose SetPoint and adjust value with Up or Down Key before press Enter and
confirm.
−
Sp_750mv___700_mv_
−
Sp_7.4ph____7.6_ph_
►
Press Cal and Set Key (both) for 5 Seconds and run Program Setup:
23.2 Program_Menu
(Press Enter to set the following Item)
►
Language_
(It’s possible to have 5 language EN, IT, SP, DE, FR)
►
Redox_Measure
−
setpoint___750_mv
(Adjust value with enter and up or down key) It’s possible to adjust from
0 to 1000 mV value for Redox
−
sp_type___low
(Adjust value LOW or HIGH)
−
ofa_time_000_min
(Adjust value OFF or set Time)
−
alarm_band__000_rx
(Adjust value from 100 to 300 mV )
►
ph_Measure
−
setpoint____7.4ph
(Adjust value with enter and up or down key) It’s possible to adjust from 0
to 14 pH value.
−
sp_type___acid
(Adjust value ACID or ALKA)
−
ofa_time_000_min
(Adjust value OFF or set Time)
−
alr_band__000_ph
(Adjust value from 1 pH to 3 pH)
−
Temp__25*C_
(Adjust value with enter and up or down key) pH measure only.
►
Flow_
(Adjust value with enter and up or down key Enable or Disable)
−
It’s possible to enable(ON) or disable (OFF) signal input
►
Calibration_probe
(Adjust value with enter and up or down key)
−
Full
(pH 7 and 4, Redox 465 mV buffer solution)
−
Easy
(pH 7, Redox 465 mV buffer solution)
−
Off
(Disabled)
►
Password
(Adjust value with enter and up or down key, standard value
0000
)
23.3 Exit______save
►
(Adjust value with up or down key and confirm with enter key)
►
Save and escape Program setup with ESC key
23.4 priming_____700mv
►
Priming Pump Keep Press UP Key for 1 seconds and priming redox pump
23.5 priming_____7.2ph
►
Priming Pump Keep Press Down Key for 1 seconds and priming pH pump