31
- GB -
Pos: 81 /Gartentechnik/KDS Anlage TEKNA/Absatz 4 @ 12\mod_1253695026504_121.doc @ 75310 @
9.
Paragraph 4 – Setting the Maximum Flow
Programming
Operation
-
-
-
Pump Functions
Max flow rate
Max flow rate
Max flow rate
P100%
P100%
F320s/m
PROG
-
+
-
+
-
This makes it possible to set the maximum flow offered by the
pump, and the programmed mode (% or frequency) is used as the
standard unit of measurement when displaying the flow. Changes
can be made by pressing the
key, then using the
keys to set the new value. Press
to confirm and return to the
main menu
Pos: 82 /Gartentechnik/KDS Anlage TEKNA/Absatz 5 @ 12\mod_1253695075077_121.doc @ 75337 @
10.
Paragraph 5 – Setting the Alarm Relay
Programming
Operation
-
-
-
-
Pump Functions
Max flow rate
Alarm Relay
P100%
N.Open
PROG
+
-
This is used to set the alarm relay in the absence of an alarm
situation, if open (default) or closed.
Changes can be made by pressing the
key, then
using the
keys to set the new value. Press
to confirm and return to the main menu
Pos: 83 /Gartentechnik/KDS Anlage TEKNA/Absatz 6 @ 12\mod_1253695128009_121.doc @ 75364 @
11.
Paragraph 6 – Flow rate Calibration
Programming
Operation
-
-
-
-
Pump Calibration
Pump Calibration
Automatic Cal.
Automatic Cal.
Automatic Cal.
Pump Calibration
0,23 cc/stroke
cc/stroke 0,23
Start 100 strok.
Strokes 100
ml 20
Manual
PROG
+
-
+
-
Pump Calibration
Automatic
The memorised cc value per strike appears in the main menu. It can
be calibrated in two different ways:
MANUAL – manually enter the cc value per strike using the
keys and confirm by pressing the
key
AUTOMATIC – the pump makes 100 strikes, which are started by
pressing the
key. At the end of this process, enter the
quantity sucked up by the pump using the
keys and
confirm by pressing the
key.
The entered figure will be used in flow calculations.