9
- GB -
Correct electrical installation
−
Electrical installations must meet the national regulations and may only be carried out by a qualified electrician.
−
A person is regarded as a qualified electrician, if, due to his/her vocational education, knowledge and experience, he
or she is capable of and authorised to judge and carry out the work commissioned to him/her. Working as a qualified
person also includes the recognition of possible hazards and the adherence to the pertinent regional and national
standards, rules and regulations.
−
For your own safety, please consult a qualified electrician.
−
The unit may only be connected when the electrical data of the unit and the power supply coincide. The unit data is
to be found on the unit type plate or on the packaging, or in this manual.
−
Ensure that the unit is fused for a rated fault current of max. 30 mA by means of a fault current protection device.
−
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use.
−
Ensure that the power connection cable cross section is not smaller than that of the rubber sheath with the identifi-
cation H05RN-F. Extension cables must meet DIN VDE 0620.
−
Protect the plug connections from moisture.
−
Only plug the unit into a correctly fitted socket.
Safe operation
−
Never operate the unit if either the electrical cables or the housing are defective!
−
Do not carry or pull the unit by its electrical cable.
−
Route all cables such that damage is excluded and nobody can trip over them.
−
Never open the unit housing or its attendant components, unless this is explicitly required in the operating instruc-
tions.
−
Only use original spare parts and accessories for the unit.
−
Never carry out technical modifications to the unit.
−
Only have repairs carried out by customer service points authorised by OASE.
−
The power connection cables cannot be replaced. When the cable is damaged, the unit or the component needs to
be disposed of.
−
Only operate the unit if no persons are in the water!
−
Keep the socket and power plug dry.
Installation
The unit can be set up either submerged (B) or dry (C). The following applies to both installation scenarios: Only
operate the unit with the shaft in the horizontal position. Never install the pump only suspended from the suction or
pressure socket. Ensure that the motor weight is additional supported in a suitable way.
Remove the filter basket for dry installation. For this purpose, turn the filter basket counter-clockwise.
Install the unit so that it is not exposed to direct sun radiation (max. 40 ºC).
Always place the unit below water level.
DMX cable connection
How to connect the Varionaut 2 to the DMX control unit
(D-E)
:
Remove the two screws from the DMX connection terminal and take off the cover cap.
Insert the plug of the DMX cable of the DMX control unit in the socket for the DMX input signal (DMX-IN) and secure by
means of the two screws.
How to connect several (max. 32) units to the DMX control unit
(F)
:
Remove the two screws and take off the cover cap.
Insert the plug of the DMX cable in the socket for the DMX output signal (DMX-OUT) and secure by means of the two
screws. Insert the other plug of the DMX cable in the socket for the DMX input signal (DMX-IN) of the next unit.