10
- GB -
Start-up
Attention! The pump must never run dry.
Possible consequence:
The pump will be destroyed.
Protective measure:
Check the water level at regular intervals. Always place the unit below water level.
This is how to connect the power supply:
Switching on:
Connect power plug to the socket. The unit switches on immediately when the power connection is
established.
Switching off:
Disconnect the power plug.
Start-up and operation are only possible with a DMX control unit.
The DMX protocol is used for signal
transmission and pump control.
What is DMX?
The designation DMX or DMX-512 stands for „Digital Multiplex“. It is a standardised digital transmission protocol used
in stage and event equipment as well as in many Oase components.
Programming the unit
The DMX channel and the mode can be changed by means of the OASE DMX control unit. To this effect, please read
the control unit operating manual.
Description Value
Serial No. (SN)
Enter the unit serial number. The serial number is indicated on the
type plate
d
.
Manufacturer ID
160
Version No.
1
DMX channel (1 to
511)
Define the DMX channel. The factory-set channel is indicated on
the type plate
c
.
Mode
1 = define the first DMX channel.
Channel assignment information
For the functions, the unit uses two channels. The first DMX channel is defined with the the OASE DMX control unit.
The first possible value is 1.
The last possible value is 511.
Channel Description
Values
Pump OFF
0 ... 10
Control mode (please do not use)
11 ... 49
Speed Control
50 ... 99
Speed Control
Charakteristic line compensation
100 ... 149
Free
150 ... 239
DMX-C 0
Error Reset
240 ... 255
DMX-C 1
Default value speed
0 ... 255