background image

Page 3

SAFETY NOTE:  An secondary on/off valve, kept in the Off Position, in a fixed piping gas supply line before the fire pit 
is required for safety when your Outdoor Fire Pit is not in use.  It also provides for convenient maintenance and 
repair.

O.

D.

E.

Casual Fireside Fire Pits are suitable for installation from 0 - 4,500 ft. elevation without modification.

M.

F. Fixed Gas piping system must be sized to provide minimum inlet pressure at the maximum flow rate (BTU/hr).  Undue 

pressure loss will occur if the pipe is too small or the run is too long.

GAS PRESSURE REQUIREMENTS:

FOR NATURAL GAS: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

3.5 inches

 (88.9 mm) water column and 

maximum inlet gas supply pressure is 

10.5 inches

 (266.7 mm) water column.

FOR PROPANE: 

 The minimum inlet gas supply pressure for purposes of input adjustment is 

8 inches

(203 mm) water column and the maximum inlet gas supply pressure is 

13 inches

 (330 mm) water column.

MANIFOLD PRESSURE REQUIREMENT:   

Liquid Propane 9.5 (241.3mm)  / Natural Gas 2.5 (63.5mm) of pressure.

DO NOT INSTALL THIS UNIT IF MINIMUM PRESSURE IS NOT AVAILABLE OR IF MAXIMUM PRESSURE IS EXCEEDED.

A. Before installing the Outdoor Fire Pit, check “Minimum Clearance to Combustibles” on page 2.

MINIMUM CLEARANCES

 must be maintained when you install this Outdoor Fire Pit.  

THERE  MUST

BE AT LEAST 60”

 (1.5 m) from the center of the burner to any combustible sidewall, ceiling, or material.  

The Outdoor Fire Pit is for outdoor use only.  DO NOT install or use this appliance inside a building,
garage, or any other enclosed area or structure including recreational vehicles, boats & sheds.  

This unit must be

installed in such a manner that proper air ventilation is maintained without obstruction at all times, and during all 
weather conditions. 

B.

C.

CHECK GAS TYPE

 (Natural Gas or Propane):  The gas supply you intend to use may not be the same that your fire pit was 

setup for or is stated on your outdoor rating plate.  

THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE

 

GAS

.  If 

the gas supply is different, 

or you wish to change to Natural Gas, you MUST have the Fire Pit Converted (directions to 

convert can be found on page 12) to the gas type you intend to use.  Any gas type conversion should be performed 
by a qualified, professional technician or licensed plumber

.  If you are unsure, contact your dealer for assistance.

INSTALLER NOTE:  This unit should be installed so that it can be removed at a later date for service.

K.

Propane Regulator Hose 

(when used):   The propane regulator hose is located inside the fire pit door panel.  When 

installed, make sure the hose is secured inside the unit and 

DOES NOT TOUCH THE BURNER PAN.

L.

Propane Regulator Hose:

  Always inspect the condition of the propane regulator hose before each operation.  Any signs of 

excessive abrasion the hose MUST BE REPLACED.  Contact your local dealer for replacement part #COM0589

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit must be closed during any pressure testing of the system at test pressures equal to or less than ½ 
psi (3.5kPa).

I.

N.

IMPORTANT SAFETY INFORMATION 

Pre-Installation & Preparation Guidelines

If the Outdoor Fire Pit is connected to a fixed piping gas supply line, the supply line is required to have an on/off gas valve 
installed before the fire pit and it must be closed during any pressure testing of the system at test pressures in excess of ½ 
psi (3.5kPa).  

G.

H.

DO NOT USE IF GAS PRESSURE IS LOWER THAN THE MINIMUM REQUIREMENT OR EXCEEDS THE MAXIMUM.

J.

Note:  The Use Of A Third Party Fire Pit Top, Media and or Components Will Void the Omni Certification
and O.W Lee Warranty. 

GAS SUPPLY PLUMBING REQUIREMENTS 

Apply only joint compounds that are resistant to all gasses on all male pipe fittings.  Make sure to tighten every joint securely.  

DO NOT use pipe joint compound to connect flare fittings

.

Содержание CASUAL FIRESIDE 51-38

Страница 1: ...ttended If this product is left operating burning unattended it may cause serious injury or property damage DANGER Report 0521GM001S WARNING Improper installation adjustment alteration service or maintenance of this gas appliance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this gas appliance WARNING Do n...

Страница 2: ...AN CAUSE SERIOUS INJURY OR DEATH FROM FIRE BURNS EXPLOSIONS OR CARBON MONOXIDE POISONING Clearances to Combustible Construction Sidewalls 60 1 5 m from center of unit Figure 1 Ceiling 60 1 5 m from top of unit to ceiling or overhang Flooring 0 Can be installed on deck slab floor etc The dimensions shown in Figure 1 are MINIMUM CLEARANCES to maintain when you install this Outdoor Fire Pit THERE MUS...

Страница 3: ...may not be the same that your fire pit was setup for or is stated on your outdoor rating plate THIS FIRE PIT IS CONSTRUCTED FOR USE WITH PROPANE GAS If the gas supply is different or you wish to change to Natural Gas you MUST have the Fire Pit Converted directions to convert can be found on page 12 to the gas type you intend to use Any gas type conversion should be performed by a qualified profess...

Страница 4: ... the fire pit top surrounding the flame and should stay away to avoid burns and clothing or long hair ignition DO NOT continue using your FIRE PIT if you smell any unusual odors or have headaches nausea or dizziness G WARNING DO NOT throw trash paper plastics or any other flammable materials into your Fire Pit WARNING DO NOT leave in operation when unattended H DO NOT use this appliance if any par...

Страница 5: ... gas at the supply LP Gas Cylinder Valve The LP Gas Cylinder must be disconnected when the appliance is not in use 4 5 6 The LP Gas Cylinder must be standing on the designed bottom base of the cylinder for proper vapor withdrawal CONNECTING AN LP GAS CYLINDER PROPANE TANK TO THE FIRE PIT Page 5 B Minimum Clearance to Combustibles Page 2 IMPORTANT BEFORE PROCEEDING CAREFULLY READ ALL OF THE IMPORTA...

Страница 6: ...ISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and cause a pop and launch outside of the fire pit which could cause damage or injury Caution should be exercised when heating up the fire pit with lava granules to normal opera...

Страница 7: ...res Figure 3 Pour the second bag of media onto the burner support Taper from the top of the burner towards the width edge Figure 1 Rectangle Burner Support and Stainless Steel Burner Figure 2 Pour the first bag of the glass media into the burner support Page 7 GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT GEM MIRRIORED AND TUMBLED GLASS MEDIA PLACEMENT Carefully inspect the carton for shipping d...

Страница 8: ...YOU MUST MAINTAIN THE LAYOUT AS SHOWN TO ENSURE PROPER OPERATION OF YOUR FIRE PIT IF YOU NEED TO REPOSITION ANY MATERIAL TO MAINTAIN THE PROPER LAYOUT USE HEAT RESISTANT GLOVES OR ALLOW MATERIAL ADEQUATE TIME TO COOL BEFORE HANDLING Note Lava granules used in a fire pit when heated up to normal operating temperatures can cause trapped gasses or moisture in the porous stone to expand and may pop an...

Страница 9: ... on Converting Your Fire Pit to a Different Gas Type on how to access the venturi the orifice Insert a small wire in the venturi orifice holes to clear passage free of spider webs or other debris Make sure to put everything back correctly when finished for proper fire pit operation and safety This is a common problem when the fire pit has not been used for an extended period of time Low or Excessi...

Страница 10: ...ructions Fire Pit Component Parts O W Lee extends a two 2 year limited warranty on all burner components under normal use and proper maintenance OW Lee will at factory option repair or replace any outdoor fire pit burner found to be defective during this warranty period Regular maintenance must be exercised as set forth in the owner s manual For more information go to www owlee com Items Not Cover...

Страница 11: ...ied professional service technician Force or attempted repair may result in fire or explosion DO NOT use this appliance if any part has been under water Immediately call a qualified professional service technician to inspect the Outdoor Fire Pit and to replace any part of the control system and any gas control that has been under water Push in the manual gas control knob slightly and turn clockwis...

Страница 12: ...ched to the orifice holder Figure 1 and unscrew the orifice holder from the burner pipe Figures 1 and 2 50 3 Remove the orifice from the holder Figure 2 and replace it with the proper sized one for your gas requirement Propane requires the smaller orifice 4 If you are converting from propane LP gas to natural gas install the air shutter sleeve so that the air intake holes are closed Figure 2 For P...

Страница 13: ...XÉRIEUR MAGNIFIQUE ET SANS DANGER POUR LE GAZ PROPANE ET NATUREL Kit de conversion Nécessite Cet appareil est conçu en tant qu appareil à surveiller Des adultes doivent être présents quand l appareil fonctionne NE PAS le laisser brûler lorsqu il n est pas surveillé Si ce produit est laissé en train de brûler sans surveillance il peut entraîner des dommages matériels ou des blessures graves DANGER ...

Страница 14: ...ON OU L UTILISATION DE VOTRE FEU EXTÉRIEUR PIT PEUT CAUSER DES BLESSURES GRAVES OU LA MORT DE FEU BURNS EXPLOSIONS OU AU MONOXYDE DE CARBONE INTOXICATION Parois 60 1 5 m du centre de l unité Figure 1 Plafond 60 1 5 m de haut de l unité au plafond ou faux Revêtement de sol 0 Peut être installé sur le pont la dalle le plancher etc Les dimensions indiquées dans la figure 1 sont MINIMUM DÉGAGEMENTS à ...

Страница 15: ...Z EST INFÉRIEURE AU MINIMUM EXIGÉ OU DÉPASSE LE MAXIMUM E POUR LE GAZ NATUREL La pression minimale d admission du gaz pour les besoins de l ajustement de l entrée est de 88 9 mm 3 5 pouces de colonne d eau WC Water Column et la pression maximale d admission est de 266 7 mm 10 5 pouces WC POUR LE PROPANE La pression minimale d admission du gaz pour les besoins de l ajustement de l entrée est de 203...

Страница 16: ...toyer la roche de lave ou en verre morceaux avec de l eau et sécher soigneusement avant d allumer Retirez toutes les toiles d araignée à l intérieur de l unité Effectuez périodiquement un contrôle visuel de la flamme du brûleur pour vous assurer qu il n a pas beaucoup changé en hauteur ou la coloration depuis le dernier être utilisé Toute modification significative de la hauteur de la flamme ou de...

Страница 17: ...un garage ou autre espace fermé 6 Le cylindre de gaz propane doit être debout sur la base inférieure du cylindre conçu pour le retrait de vapeur appropriée LA BOUTEILLE LP GAS Réservoir de propane INFORMATION 1 2 Le cylindre s de gaz propane à utiliser doit être construit et marqué en conformité avec le Département des États Unis Transport D Ö T Spécifications pour GPL Cylindres ou la norme pour l...

Страница 18: ...e rechange en cuivre nº 6 Connecteur de bouteille de propane nº 7 Orifice nº 8 Kit de conversion de gaz propane en gaz naturel nº 9 Kit de conversion de gaz naturel en gaz propane Approved Media nº 10 Kit de rocs en céramique avec granules de lave nº 11Kit de morceaux de verre érodés taille nº 3 9 12 mm 3 8 po nº 12 Kit de bûches en céramique avec granules de lave nº 13 Granules de lave 9 mm 3 8 p...

Страница 19: ...er la disposition comme indiqué pour assurer le bon fonctionnement de votre feu PIT SI VOUS nécessité de repositionner TOUT MATÉRIEL POUR MAINTENIR l aménagement utiliser la chaleur GANTS résistants ou laisser le matériel suffisamment de temps pour COOL avant l utilisation GEM MIROIR ET TOMBA VERRE PLACEMENT DANS LES MEDIAS A Inspecter le carton avec soin pour s assurer qu il n a pas été endommagé...

Страница 20: ...ENIR LA DISPOSITION TELLE QU ILLUSTRÉE AFIN D ASSURER LE BON FONCTIONNEMENT DU FOYER SI UN MATÉRIAU DOIT ÊTRE REPOSITIONNÉ POUR MAINTENIR UN ARRANGEMENT ADÉQUAT EMPLOYER DES GANTS RÉSISTANT À LA CHALEUR OU LAISSER LE MATÉRIAU EFROIDIR AVANT DE LE MANIPULER Remarque Granulés de lave utilisés dans un puits du feu lorsque chauffés à des températures normales de fonctionnement peuvent provoquer des ga...

Страница 21: ...et l orifice Insérez un petit fil dans le venturi et orifices des trous pour dégager le passage libre des toiles d araignées ou d autres débris Assurez vous de tout remettre correctement lorsque vous avez terminé pour le fonctionnement du foyer adéquat et la sécurité Ceci est un problème commun lorsque le foyer n a pas été utilisé pendant une longue période de temps Flamme faible ou excessive Util...

Страница 22: ... Parties Pit Fire O W Lee offre une garantie limitée de deux 2 ans sur tous les composants du brûleur en utilisation normale et appropriée entretien OW Lee sera à l usine de réparer ou de remplacer tout brûleur extérieur foyer trouvé défectueux pendant cette période de garantie Un entretien régulier doit être exercé selon dans le manuel du propriétaire Pour plus d informations consultez www owlee ...

Страница 23: ...nter une réparation peut entraîner un incendie ou une explosion NE PAS EMPLOYER cet appareil si une partie ou pièce s est trouvée sous l eau Appeler immédiatement un technicien professionnel et qualifié pour inspecter le foyer et remplacer le cas échéant des pièces du système de contrôle et de commande du gaz qui se sont trouvées sous l eau INSTRUCTIONS D ALLUMAGE STOP LIRE LES MESURES DE SÉCURITÉ...

Страница 24: ...ler le manchon de l obturateur d air de telle sorte que les orifices d admission d air sont fermées Figure 2 Pour le gaz propane retirez l obturateur d air de telle sorte que les orifices d admission d air sont ouverts Figure 1 Après que l appareil est assemblé à l emploi il est besoin d un contrôle de fuite test sur toutes les connexions sont avant de placer l unité en fonctionnement 5 IL EST NÉC...

Отзывы: