NXP Semiconductors
UM191812
PN544 C2 User Manual
191812
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2010. All rights reserved.
User Manual
Rev. 1.2 — 2010-06-16
49 of 172
Value Description
0x02 Type
F
0x03 No
modulation
others RFU
Baud rate indicates the RF modulation bitrates to be used for the test
Table 35.
PRBS test Command Bitrate Parameter
Value Description
0x00 106
kbps
0x01 212kbps
0x02 424
kbps
others RFU
Table 36.
Autonomous Event
Value Event
Description
‘01’
NXP_EVT_SET_AUTONOMOUS This event is sent by the host to put the system
in Autonomous mode
Note:
This event is interesting to inform PN544 when Host keep PVDD available and
does not want to communicate on Host Link anymore. If Host is going to disable PVDD,
this event is not mandatory; PN544 will switch in Autonomous mode automatically.
Table 37.
Information Event
Value Event
Description
‘10’ NXP_EVT_INFO_TXLDO_OVERCUR
This event is sent to the host to inform
about overcurrent issue.
‘11’ NXP_EVT_INFO_PMUVCC
This event is sent to the host to inform
about PmuVcc signal switch which can
then impact SimVcc (implies internal
reactivation of the SWP link).