Chapter 10
Known issues/errata for revision D
• Change R547, R548 with RES 12 K from 4.7 K.
• Update layout for DMICs:
— Microphones U120 and U121 to be placed 66 cm apart.
— Acoustic holes should face to the top and not to the bottom.
NXP Semiconductors
MIMXRT595 EVK Board Hardware User's Guide, Rev. 0, 02/2021
User's Guide