Serial Communication Interface (S12SCIV5)
S12XS Family Reference Manual, Rev. 1.13
Freescale Semiconductor
409
14.3.2.7
SCI Status Register 1 (SCISR1)
The SCISR1 and SCISR2 registers provides inputs to the MCU for generation of SCI interrupts. Also,
these registers can be polled by the MCU to check the status of these bits. The flag-clearing procedures
require that the status register be read followed by a read or write to the SCI data register.It is permissible
to execute other instructions between the two steps as long as it does not compromise the handling of I/O,
but the order of operations is important for flag clearing.
Read: Anytime
Write: Has no meaning or effect
Module Base + 0x0004
7
6
5
4
3
2
1
0
R
TDRE
TC
RDRF
IDLE
OR
NF
FE
PF
W
Reset
1
1
0
0
0
0
0
0
= Unimplemented or Reserved
Figure 14-10. SCI Status Register 1 (SCISR1)
Table 14-11. SCISR1 Field Descriptions
Field
Description
7
TDRE
Transmit Data Register Empty Flag — TDRE is set when the transmit shift register receives a byte from the
SCI data register. When TDRE is 1, the transmit data register (SCIDRH/L) is empty and can receive a new value
to transmit.Clear TDRE by reading SCI status register 1 (SCISR1), with TDRE set and then writing to SCI data
register low (SCIDRL).
0 No byte transferred to transmit shift register
1 Byte transferred to transmit shift register; transmit data register empty
6
TC
Transmit Complete Flag — TC is set low when there is a transmission in progress or when a preamble or break
character is loaded. TC is set high when the TDRE flag is set and no data, preamble, or break character is being
transmitted.When TC is set, the TXD pin becomes idle (logic 1). Clear TC by reading SCI status register 1
(SCISR1) with TC set and then writing to SCI data register low (SCIDRL). TC is cleared automatically when data,
preamble, or break is queued and ready to be sent. TC is cleared in the event of a simultaneous set and clear of
the TC flag (transmission not complete).
0 Transmission in progress
1 No transmission in progress
5
RDRF
Receive Data Register Full Flag — RDRF is set when the data in the receive shift register transfers to the SCI
data register. Clear RDRF by reading SCI status register 1 (SCISR1) with RDRF set and then reading SCI data
register low (SCIDRL).
0 Data not available in SCI data register
1 Received data available in SCI data register
4
IDLE
Idle Line Flag — IDLE is set when 10 consecutive logic 1s (if M = 0) or 11 consecutive logic 1s (if M =1) appear
on the receiver input. Once the IDLE flag is cleared, a valid frame must again set the RDRF flag before an idle
condition can set the IDLE flag.Clear IDLE by reading SCI status register 1 (SCISR1) with IDLE set and then
reading SCI data register low (SCIDRL).
0 Receiver input is either active now or has never become active since the IDLE flag was last cleared
1 Receiver input has become idle
Note: When the receiver wakeup bit (RWU) is set, an idle line condition does not set the IDLE flag.
Содержание MC9S12XS128
Страница 4: ...S12XS Family Reference Manual Rev 1 13 4 Freescale Semiconductor ...
Страница 58: ...Device Overview S12XS Family S12XS Family Reference Manual Rev 1 13 58 Freescale Semiconductor ...
Страница 150: ...Memory Mapping Control S12XMMCV4 S12XS Family Reference Manual Rev 1 13 150 Freescale Semiconductor ...
Страница 168: ...Interrupt S12XINTV2 S12XS Family Reference Manual Rev 1 13 168 Freescale Semiconductor ...
Страница 194: ...Background Debug Module S12XBDMV2 S12XS Family Reference Manual Rev 1 13 194 Freescale Semiconductor ...
Страница 364: ...Periodic Interrupt Timer S12PIT24B4CV1 S12XS Family Reference Manual Rev 1 13 364 Freescale Semiconductor ...
Страница 396: ...Pulse Width Modulator S12PWM8B8CV1 S12XS Family Reference Manual Rev 1 13 396 Freescale Semiconductor ...
Страница 506: ...Voltage Regulator S12VREGL3V3V1 S12XS Family Reference Manual Rev 1 13 506 Freescale Semiconductor ...
Страница 736: ...Ordering Information S12XS Family Reference Manual Rev 1 13 736 Freescale Semiconductor ...
Страница 737: ......