• Other conditions: Ci, 90 pF; vdd3v, 3.3 V; S_XIN, 1/4; S_XCH, 1/2.
•
: Configure the Decimation, Order, and Cutoff as 1, and the final scan result is 110. TSI performs scan
operation for one time, and the scan time is 239 μs.
•
: Change the Decimation to 2, and the final scan result becomes 220. TSI performs scan twice, and the scan
time is 448, about twice of the previous 239 μs.
•
16 times, and the scan time is 3390 μs, saving time by setting order = 2.
By comparing the test results when setting order to 1 and order to 2, the conclusion is:
Increasing TSI conversion result (TSICNT) means to cost longer scan time. When TSI performs multiple scans, it is recommended
to set order to 2 to reduce interference and save touch electrode scan time. Then change the Decimation and Cutoff to adjust the
TSI conversion result. Increase TSI conversion result means longer scan time.
The scan time in this table is measured by the LPTMR module. That is, start LPTMR on the TSI scan start, stop LPTMR on the
TSI scan end, and then read the LPTMR counter to estimate the time cost. There are some inevitable small errors and differences
between LPTMR measurement and real TSI scan time.
2.5.2 Sensitivity test result when sensitivity boost feature enable
When the sensitivity boost function is enabled, NSTEP is calculated by
, and the calculation of TSICNT and scan time
still uses
The sensitivity boost configurations include: S_SEN Enable, S_CTRIM, and Multiplier (S_XDN/S_XCH).
Table 9. Sensitivity boost configurations registers
Variable
Register
Descriptions
S_SEN Enable
TSI_MODE[S_SEN]
Enable sensitivity boost by setting S_SEN to 1.
S_CTRIM
TSI_MODE[S_CTRIM]
Remove the parasitic capacitance virtually, from 2.5 pF to 20 pF.
Multiplier:
S_XDN/S_XCH
TSI_MODE[S_XDN]
Multiplier factor when sensitivity boost is enabled.
TSI_MODE[S_XCH]
Charge/discharge multiple
The remove capacitance is:
Cremoved = S
CTRIM
× S
XDN
S
XCH
Equation 9.
Table 10. Sensitivity test for sensitivity boost configurations
Current Amplifier
Sensitivity Boost
Intrinsic
capacitance
calculated Cx
Sensitivity
calculated
(%)
S_XIN S_XCH
Current Amplifier
(S_XIN*S_XCH)
S_SEN
Enable
S_XDN
S_Ctrim
(pF)
C
removed
(pF)
1/4
1/2
1/8
OFF
1/2
2.5
0.0
16
11.6
1/4
1/2
1/8
ON
1/2
2.5
2.5
16
12.5
Table continues on the next page...
NXP Semiconductors
TSI self-cap mode introduction
KE17Z Dual TSI User Guide, Rev. 0, 05 May 2022
User Guide