11990-190/192
Shelf Management
55
R1.0, October 2018
20
173
0
PEM B Branch 1
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 1
of PEM B.
20
174
0
PEM B Branch 2
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 2
of PEM B.
20
175
0
PEM B Branch 3
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 3
of PEM B.
20
176
0
PEM B Branch 4
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 4
of PEM B.
20
177
0
PEM B Branch 5
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 5
of PEM B.
20
178
0
PEM B Branch 6
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 6
of PEM B.
20
180
0
Shelf Power
Power Supply
0x08
Threshold
This sensor measures the total input
power of the shelf as a sum of both
PEMs.
5a = Lower Fan Tray
5a
0
0
HOT SWAP
Hot Swap
0xf0
Discrete
This sensor returns the hot-swap
states.
5a
1
0
Version Change
reserved
0x2b
Discrete
This sensor indicates a hardware or
software change.
5a
2
0
IPMB Physical
IPMB Link
0xf1
Discrete
This sensor returns the IPMB link
state.
5a
3
0
Telco Alarm
TELCO Alarm Input
0xf4
Discrete
Telco alarm input sensor.
5a
4
0
+3.3V
Voltage
0x02
Threshold
This sensor measures the local 3.3 V
voltage in volts.
5a
5
0
+3.6V External
Voltage
0x02
Threshold
This sensor measures the external
3.6 V voltage in volts.
5a
6
0
Temp Controller
Temperature
0x01
Threshold
This sensor measures the temperature
of the IPM Controller.
5a
7
0
Temp_In Left
Temperature
0x01
Threshold
This sensor measures the left inlet
temperature.
5a
8
0
Temp_In Center
Temperature
0x01
Threshold
This sensor measures the central inlet
temperature.
5a
9
0
Temp_In Right
Temperature
0x01
Threshold
This sensor measures the right inlet
temperature.
5a
10
0
Fan Tach. 1
Fan
0x04
Threshold
This sensor indicates the speed of the
fan 1 (RPM).
5a
11
0
Fan Tach. 2
Fan
0x04
Threshold
This sensor indicates the speed of the
fan 2 (RPM).
5a
12
0
Fan Tach. 3
Fan
0x04
Threshold
This sensor indicates the speed of the
fan 3 (RPM).
5a
13
0
Fan Tach. 4
Fan
0x04
Threshold
This sensor indicates the speed of the
fan 4 (RPM).
5a
14
0
Fan Tach. 5
Fan
0x04
Threshold
This sensor indicates the speed of the
fan 5 (RPM).
5a
15
0
Fan Tach. 6
Fan
0x04
Threshold
This sensor indicates the speed of the
fan 6 (RPM).
5a
16
0
Air Filter
OEM reserved
0xc0
Discrete
This sensor checks the presence of the
air filter.
5a
17
0
-48V A Branch 1
OEM reserved
0xc0
Discrete
This sensor indicates the presence of
the –48 V_A branch 1 at the lower fan
tray connector.
IPMC
Nr.
LUN Name
Type
Type-
Code
Class
Description
Содержание SCHROFF 11990-19 Series
Страница 1: ...14U 14 slot ATCA Shelf User Manual Product Number 11990 190 192 Doc No 63972 374_R1 0 October 2018...
Страница 30: ...11990 190 192 Thermals 26 R1 0 October 2018 7 3 Front slot measurement zones...
Страница 68: ...11990 190 192 Technical Data 64 R1 0 October 2018...
Страница 69: ......
Страница 70: ...Schroff GmbH Langenalber Str 96 100 75334 Straubenhardt Germany Tel 49 7082 794 0 Fax 49 7082 794 200...