![nvent SCHROFF 11990-19 Series Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/nvent/schroff-11990-19-series/schroff-11990-19-series_user-manual_1720736058.webp)
11990-190/192
Shelf Management
54
R1.0, October 2018
20
131
0
TELCO Alarms
OEM reserved
0xdf
Discrete
This sensor indicates the presence of
critical, major and minor alarm.
20
132
0
BMC Watchdog
Watchdog 2
0x23
Discrete
BMC watchdog sensor.
20
133
0
SYSTEM EVENT
System Event
0x12
Discrete
System event sensor.
20
135
0
FT Oper.Status
Management Sub-
syst. Health
0x28
Discrete
This sensor monitors if all the fan trays
are operational or if some fan trays is
not operation.
20
136
0
Cooling State
Management Sub-
syst. Health
0x28
Discrete
This sensor monitors the cooling sta-
tus.
20
137
0
Fans State
Management Sub-
syst. Health
0x28
Discrete
This sensor monitors the fan status.
20
138
0
SHM Redundancy
Management Sub-
syst. Health
0x28
Discrete
This sensor monitors the shelf man-
ager redundancy status.
20
140
0
PEM A Temp
Temperature
0x01
Threshold
This sensor measures the PEM A tem-
perature.
20
141
0
PEM B Temp
Temperature
0x01
Threshold
This sensor measures the PEM B tem-
perature.
20
150
0
Air Filter
Entity Presence
0x25
Discrete
This sensor checks the presence of the
air filter.
20
151
0
CDM 1 Pres
Entity Presence
0x25
Discrete
This sensor indicates the presence of
CDM 1.
20
152
0
CDM 2 Pres
Entity Presence
0x25
Discrete
This sensor indicates the presence of
CDM 2.
20
153
0
PEM A Pres
Entity Presence
0x25
Discrete
This sensor indicates the presence of
PEM A
20
154
0
PEM B Pres
Entity Presence
0x25
Discrete
This sensor indicates the presence of
PEM B.
20
155
0
Fan Tray 1 Pres
Entity Presence
0x25
Discrete
This sensor indicates the presence of
fan tray 1. (lower fan tray)
20
156
0
Fan Tray 2 Pres
Entity Presence
0x25
Discrete
This sensor indicates the presence of
fan tray 2. (upper fan tray)
20
160
0
PEM A Voltage
Voltage
0x02
Threshold
This sensor measures the output volt-
age of PEM A.
20
161
0
PEM A Current
Current
0x03
Threshold
This sensor measures the output cur-
rent of PEM A. (Optional)
20
162
0
PEM A Power
Power Supply
0x08
Threshold
This sensor measures the input power
of PEM A in the past hour. (Optional)
20
163
0
PEM A Branch 1
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 1
of PEM A.
20
164
0
PEM A Branch 2
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 2
of PEM A.
20
165
0
PEM A Branch 3
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 3
of PEM A.
20
166
0
PEM A Branch 4
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 4
of PEM A.
20
167
0
PEM A Branch 5
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 5
of PEM A.
20
168
0
PEM A Branch 6
Entity Presence
0x25
Discrete
This sensor indicates the presence of
the voltage after the fuse on branch 6
of PEM A.
20
170
0
PEM B Voltage
Voltage
0x02
Threshold
This sensor measures the output volt-
age of PEM B.
20
171
0
PEM B Current
Current
0x03
Threshold
This sensor measures the output cur-
rent of PEM B. (Optional)
20
172
0
PEM B Power
Power Supply
0x08
Threshold
This sensor measures the input power
of PEM B in the past hour. (Optional)
IPMC
Nr.
LUN Name
Type
Type-
Code
Class
Description
Содержание SCHROFF 11990-19 Series
Страница 1: ...14U 14 slot ATCA Shelf User Manual Product Number 11990 190 192 Doc No 63972 374_R1 0 October 2018...
Страница 30: ...11990 190 192 Thermals 26 R1 0 October 2018 7 3 Front slot measurement zones...
Страница 68: ...11990 190 192 Technical Data 64 R1 0 October 2018...
Страница 69: ......
Страница 70: ...Schroff GmbH Langenalber Str 96 100 75334 Straubenhardt Germany Tel 49 7082 794 0 Fax 49 7082 794 200...