![nvent SCHROFF 11990-19 Series Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/nvent/schroff-11990-19-series/schroff-11990-19-series_user-manual_1720736052.webp)
11990-190/192
Shelf Management
48
R1.0, October 2018
9.7 Hot Swap Interface
The Shelf Manager provides a Hot Swap interface allowing the Shelf Manager
to be replaced without powering down the Shelf. The interface is composed of
three components:
•
Hot Swap switch at injector/ejector handle
•
Presence signal indicating that the Shelf Manager is fully seated in its
backplane connector
•
Hot Swap LED
9.7.1 Hot Swap LED
The Shelf Manager provides a a blue Hot Swap LED. The LED indicates when
it is safe to "remove" the Shelf Manager from a powered Shelf.
Table 11: Hot Swap LED
9.8 Hardware Address
The Shelf Manager reads the hardware address and parity bit from the
backplane connector of the Dedicated Shelf Manager slot. Geographic address
pins (HA[0], HA7) at the Backplane connector determine bit 0 and bit 7, bit 1...6
are hardware-coded on the Shelf Manager PCB.
LED State
Condition
Off
The Shelf Manager is not ready to be removed/disconnected from the Shelf
Solid Blue
The Shelf Manager is ready to be removed/disconnected from the Shelf
Long-blink
The Shelf Manager is activating itself
Short-blink
Deactivation has been requested
HW-Addr.
IPMB-Addr.
HA[0]
HA7
Shelf Manager 1
0x08
0x10
GND
GND
Shelf Manager 2
0x09
0x12
n.c.
n.c.
Содержание SCHROFF 11990-19 Series
Страница 1: ...14U 14 slot ATCA Shelf User Manual Product Number 11990 190 192 Doc No 63972 374_R1 0 October 2018...
Страница 30: ...11990 190 192 Thermals 26 R1 0 October 2018 7 3 Front slot measurement zones...
Страница 68: ...11990 190 192 Technical Data 64 R1 0 October 2018...
Страница 69: ......
Страница 70: ...Schroff GmbH Langenalber Str 96 100 75334 Straubenhardt Germany Tel 49 7082 794 0 Fax 49 7082 794 200...