Power/
Termination
Module
Power/
Termination
Module
CAN/Term
CAN/Term CAN / 24 Vdc
CAN / 24 Vdc
Power/
Termination
Module
Power/
Termination
Module
CAN/Term
CAN/Term CAN / 24 Vdc
CAN / 24 Vdc
Power/
Termination
Module
Power/
Termination
Module
CAN/Term
CAN/Term CAN / 24 Vdc
CAN / 24 Vdc
Power/
Termination
Module
Power/
Termination
Module
CAN/Term
CAN/Term CAN / 24 Vdc
CAN / 24 Vdc
IN
IN
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 10
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 4
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 3
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 2
IN
IN
OUT
OUT
CAN / 24 Vdc
Bridge
Module
80 Modules
per Bridge
Module 1
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
IN
IN
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 20
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 14
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 13
IN
IN
OUT
OUT
CAN / 24 Vdc
Primary
or
I/O
Module 12
IN
IN
OUT
OUT
CAN / 24 Vdc
Bridge
Module
80 Modules
per Bridge
Module 11
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
IN
IN
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 30
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 24
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 23
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 22
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 21
++
––
20 Modules
per Power Supply
20 Modules
per Power Supply
100-240 Vac In
100-240 Vac In
20 Modules
per Power Supply
20 Modules
per Power Supply
100-240 Vac In
100-240 Vac In
Optional redundant supply
Optional redundant supply
++
––
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
IN
IN
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 40
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 34
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 33
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 32
IN
IN
OUT
OUT
CAN / 24 Vdc
HTC/HTC3
or
I/O
Module 31
Termination
Block
Termination
Block
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
CAN / 24 Vdc
++
––
20 Modules
per Power Supply
20 Modules
per Power Supply
Termination
Block
Termination
Block
100-240 Vac In
100-240 Vac In
20 Modules
per Power Supply
20 Modules
per Power Supply
100-240 Vac In
100-240 Vac In
Optional redundant supply
Optional redundant supply
++
––
CAN / 24 Vdc
CAN / 24 Vdc
Primary Supply*
24 Vdc
Primary Supply*
24 Vdc
Redundant Supply*
24 Vdc
Redundant Supply*
24 Vdc
Primary Supply*
24 Vdc
Primary Supply*
24 Vdc
Redundant Supply*
24 Vdc
Redundant Supply*
24 Vdc
* Power supply
shall have a
means for
disconnect from
line voltage
NGC-40 CAN Bus Connections for Up to 40 Modules
nVent.com
©2018 nVent. All nVent marks and logos are owned or licensed by nVent Services GmbH or its affiliates. All other trademarks are the property of their respective owners.
nVent reserves the right to change specifications without notice.
Raychem-IM-H58088-NGCIO-EN-1805
PCN 1244-009549
North America
Tel +1.800.545.6258
Fax +1.800.527.5703
Europe, Middle East, Africa
Tel +32.16.213.511
Fax +32.16.213.604
Asia Pacific
Tel +86.21.2412.1688
Fax +86.21.5426.3167
Latin America
Tel +1.713.868.4800
Fax +1.713.868.2333