GENERAL

Supply voltage

24 Vdc ± 10%

Internal power consumption

< 2.4 W per NGC-40-IO

Ambient operating temperature

–40ºC to 65ºC (–40ºF to 149ºF)

Ambient storage temperature

–40ºC to 75ºC (–40ºF to 167ºF)

Environment

PD2, CAT III

Max. altitude

2,000 m (6,562 ft)

Humidity

5 – 90% noncondensing

Mounting

Din Rail – 35 mm

ELECTROMAGNETIC COMPATIBILITY

Emissions

EN 61000-6-3  Emission standard for residential, commercial and light industrial environments

Immunity

EN 61000-6-2 Immunity standard for industrial environments

Temperature Sensors
Type

100 Ω platinum RTD, 3-wire, α = 0.00385 ohms/ohm/ºC Can be extended with a 3-conductor 

shielded cable of 20 Ω maximum per conductor
100 Ω, Ni-Fe, 2-wire Can be extended with a 2-wire shielded cable of 20 Ω maximum per 

conductor

Quantity 

Up to four wired directly to each NGC-40-IO module

ALARM RELAY

Dry contact relay (voltage free)

Relay contact rated 250 V / 3 A  

50/60 Hz (EC) and 277 V / 3 A  

50/60 Hz (cCSAus).  

Output is user programmable to flash. N0 and NC contacts available.

DIGITAL INPUT

Multi-purpose input

Multi-purpose input for connection to external dry (voltage-free) contact or DC voltage. May 

be user programmable for: not used / force off / force on functions. It can be configured to be 

active open or active closed.

Max. input voltage

24 Vdc

CAN NETWORKING PORT

Type

2-wire isolated CAN-based peer-peer network. Isolated to 300 V.

Connection

Two 8-pin RJ-45 connectors (both may be used for Input or Output connections

Protocol

Proprietary NGC-40

Topology

Daisy chain

Length

10 m (33 ft) maximum

Quantity

Up to 80 HTC/HTC3 and IO modules per network segment

Address

Unique, factory assigned

CONNECTION TERMINALS

Wiring terminals

Cage clamp, 0.5 to 2.5 mm2 (24 to 12 AWG)

CAN networking and module power

Two RJ-45s, one each IN and OUT. Provides CAN bus signals and +24 Vdc power.

HOUSING

Size

45.1 mm (1.78 in) wide x 87 mm 

(3.43 in) high x 106.4 mm (4.2 in) deep

Содержание RAYCHEM NGC-40-IO

Страница 1: ...nnections CAN Termination Resistor KIT CONTENTS Item Qty Description A 1 NGC 40 IO module This component is an electrical device that must be installed correctly to ensure proper operation and to prev...

Страница 2: ...relay voltage free Relay contact rated 250 V 3 A 50 60 Hz EC and 277 V 3 A 50 60 Hz cCSAus Output is user programmable to flash N0 and NC contacts available DIGITAL INPUT Multi purpose input Multi pu...

Страница 3: ...module Off No power Green OK Normal Yellow Configuration mode Red Internal fault NETWORK Indicates CAN network activity Off No link detected Green Link OK receive data packets Yellow Transmit data pac...

Страница 4: ...block Field terminal block 13 13 14 14 15 15 16 16 Filed terminal block Filed terminal block TS2 TS2 TS1 TS1 21 21 22 22 23 23 24 24 Field terminal block Field terminal block TS4 TS4 TS3 TS3 17 T S CO...

Страница 5: ...t 7 7 8 8 Terminal block Terminal block Earth grounding bar located at the I O module Earth grounding bar located at the I O module From user input From user input Digital Input Digital Input North Am...

Страница 6: ...ations for the NGC 40 IO assembly in the electrical panel The NGC 40 IO should be located in the rear of the panel The NGC 40 IO assembly is an electronic unit and must not be located where it will be...

Страница 7: ...n Module CAN 24 Vdc Primary Supply 24 Vdc Primary Supply 24 Vdc Power supply shall have a means for disconnect from line voltage Power supply shall have a means for disconnect from line voltage Redund...

Страница 8: ...ptional redundant supply CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc CAN 24 Vdc IN IN OUT CAN 24 Vdc HTC HTC3 or I O Module 40 IN IN OUT OUT CAN 24 Vdc HTC...

Отзывы: