PLEASE READ CAREFULLY PRIOR TO

 

Troubleshooting and Servicing Electrical Equipment

 

 

Definitions 

WARNING 

 May cause serious injuries or death

 

CAUTION

 

 May cause property damage

 

For information on NuWhirl Instructions, see: 

www.nuwhirl.com/doc/product-instructions.html 

 

When installing and using this electrical equipment, basic safety 
precautions should always be followed, including: 

Important Safety Instructions

 

WARNING 

Keep  dry.  Replace  control  if 

exposed to water, moisture or contamination.

 

 

WARNING

 

Use and follow these instructions 

along  with  all  instructions  that  have  been 

provided.

 

 

WARNING

 

Electronic  control  system 

components  should  be  installed  as  per  local 

and national Electrical Codes, in a location not 

to  be  subjected  to  splashing  or  flooding. 

Exposure  to  water  or  splashing  will  void  all 

product certifications and warranties. 

 

There  are  no  user  serviceable  parts  inside.  

Opening, modifying, or tampering with control 

system  components  will  void  all  product 

certifications and warranties. 

 

WARNING

 

Risk  of  electric  shock.  Connect 

only to a ground type receptacle protected by 

a  Ground-Fault  Circuit  Interrupter  (GFCI).  

Contact  a  qualified  electrician  if  you  cannot 

verify that the power supply is protected by a 

GFCI. The GFCI should be tested on a routine 

basis.  Consult  the  GFCI  manufacturer’s 

instructions for correct testing and operation  

 

For electrical connections, see applicable 

wiring diagram.   

See www.nuwhirl.com/doc/product-

instructions.html 

 

 

Do not use an extension cord to connect the 

product to the electric supply; provide a properly 

located receptacle. 

 

WARNING

   

Failure to install in strict accordance 

with  each  and  every  instruction  above  may 

compromise  the  system,  which  may  cause 

injury to persons and/or property. 

 

The tub may be supplied from more than one 

power source.  Before working on any electrical 

device,  make  sure  all  power  to  the  control 

system is off. 

 

Use  this  unit  only  for  its  intended  use  as 

described  in  this  manual.  Do  not  use 

attachments  not  recommended  by  the 

manufacturer.  Any  improper  installation  or 

misuse of the equipment may result in injury to 

the user and will void the warranty. 

 

Do not run unit dry. Always be certain that the 

pump casing is filled with water before starting 

the  unit.  If  pump  fails  to  prime  within  30 

seconds, turn it off. Check if there is an airlock, 

clogged plumbing, or closed valve.  

  
 

 
Save these instructions. 

Содержание TOUCHSTONE CSLC-317-02-01-01

Страница 1: ...317 02 01 01 Single Load Controller Multi Speed Triac Load Installation Operating Manual with Troubleshooting and Configuration Guide NuWhirl Systems Corp www nuwhirl com 951 817 5600 MANCSLC31702 REV...

Страница 2: ...by a Ground Fault Circuit Interrupter GFCI Contact a qualified electrician if you cannot verify that the power supply is protected by a GFCI The GFCI should be tested on a routine basis Consult the G...

Страница 3: ...ration P 4 Important Installation Notes Mounting P 6 CSLC 317 02 01 01 Multi Speed Air Blower Triac Model Installation Feature Operations P 8 Operations P 10 System Troubleshooting P 14 All Installati...

Страница 4: ...hese are the configurations currently available as of September 22 2021 CSLC 317 02 01 01 Triac Model CAUTION Ensure that the Controller Model is suitable for the Tub s Load that is to be controlled F...

Страница 5: ...from the AC power and wait about 10 seconds 3 Plug the control box back in The green Power LED will blink the current configuration that it is in 4 Within 20 seconds press and hold the Configuration B...

Страница 6: ...t have a center screw Load This Controller is only compatible with 120 Volt Brush Type Pumps and Brush Type Blowers with a Maximum Rating of 12 Amps Plug the Load into the Receptable at the bottom of...

Страница 7: ...overtighten 4 Turn the power back on and confirm correct operation Note If the remaining receptacle above the Controller is being used the total load must not exceed the circuit s rating Additional In...

Страница 8: ...12 CICL 297 Tub Lights x2 Max Configs 1 thru 6 Air Switch Option Configs 1 7 thru 12 To 120V GFCI Protected Receptacle 15A or 20A Duplex Female Socket TO PUMP OR BLOWER Max 12A Load CCBL 372 CCBL 366...

Страница 9: ...to fully understand and safely utilize the tub System Features Air Buttons Function Timers Variable Speed Pump or Variable Speed Blower Multi Color LED Tub Lights Activation Air Switch Buttons which m...

Страница 10: ...its 30 minute timer and activate the Tub Light in a Rainbow mode Subsequent presses will change the color to Blue White Blue Aqua Green Yellow Red Magenta and off The Tub Light will turn off automati...

Страница 11: ...the Blower on at high speed and activate its 30 minute timer Subsequent presses will change the speed to medium low oscillate mode and off The system will stop automatically when the timer expires The...

Страница 12: ...the speed to medium low oscillate mode and off The system will stop automatically when the timer expires Configuration 8 Variable Speed Pump w Oscillation Option No Light The Whirlpool Water system is...

Страница 13: ...the Button a third time turn the Blower off Configuration 12 Variable Speed Blower w Oscillation Option No Light 24 Hour Purge Cycle The Air System is activated by pressing the Air Air Button The Air...

Страница 14: ...f these cables were cross connected or forced in at any point irreparable damage may result and any warranty will be void Should this happen replace all the affected components ensuring that they are...

Страница 15: ...not function verify that the Load is operational by plugging it directly into a known good wall receptacle If not replace the Control Box or Load accordingly Non Functional Keypad If the Keypad is not...

Страница 16: ...tems Corp www nuwhirl com 951 817 5600 MANCSLC31702 REV A 9 27 2021 Retain this manual for future reference For your records and future reference please fill in data below Manufacturer Model Serial Da...