32
Encoder User Manual
※ Configuration requirements of camera and surrounding area
1. Auto-focusing function should not be enabled for intrusion detection.
2. Avoid the scenes with many trees or the scenes with various light changes (like many flashing
headlights). The ambient brightness of the scenes shouldn’t be too low.
3. Cameras should be mounted at a height of 2.8 meters or above.
4. Keep the mounting angle of the camera at about 45°.
5. The detected objects should not be less than 1% of the entire image and the largest sizes of
the detected objects should not be more than 1/8 of the entire image.
6. Make sure cameras can view objects for at least 2 seconds in the detected area for accurate
detection.
7. Adequate light and clear scenery are crucial to line crossing detection.
4.6
Network Configuration
4.6.1
TCP/IP
Go to Config
→
Network
→
TCP/IP interface as shown below. There are two ways for network
connection.
Use IP address (take IPv4 for example)-
There are two options for IP setup: obtain an IP
address automatically by DHCP protocol and use the following IP address. Please choose one
of the options for your requirements.
Use PPPoE-
Click “PPPoE Config” tab to go to the interface as shown below. Enable PPPoE
and then enter the user name and password from your ISP.