18
Mini PTZ Speed Dome
• Connecting Video output
Figure 2 – Basic installation diagram
• Connecting Alarms
AL1 to 4 (Alarm In)
Magnetic, PIR or other external sensor devices can be used to signal the
dome camera reacting to an event.
See Chapter 3.2 — Program and Operation for configuring alarm input.
GND (Ground)
NOTE: All the connectors marked
GND
are common.
Connect the ground of the Alarm input and/or alarm output to the GND
connector.
NO / NC (Normally Opened or Normally Closed dry contact relay output)
The dome camera can activate external devices such as buzzers or lights
using dry contact relays. Connect the device to the NO (NC) (Alarm Out) and
COM (Common) connectors. See Chapter 3 — Program and Operation for
configuring alarm output.
• Connecting the Power
Connect AC 24V 40VA power to the dome camera.
Use certified / Listed Class 2 power supply transformer only.