background image

14 •

Camera Control & Setup

Use the five key on switch board of the camera.

RIGHT key

LEFT key

UP key

DOWN key

CENTER key

Service Monitor Output

• 15

OSD Menu Instructions

Main Menu

LENS

SHUTTER

WHITE BALANCE

BACKLIGHT

AGC

DNR

DSS

Menu & Setting Details

• DC
• MANUAL
• NONE
• FLK
• ESC
• MANUAL
• ATW
• MANUAL

• AWC
• OFF
• LOW
• MIDDLE
• HIGH
• OFF
• LOW
• MIDDLE
• HIGH
• OFF
• LOW 
• MIDDLE
• HIGH
• OFF
• AUTO

BRIGHTNESS 

BRIGHTNESS 
SHUTTER 
MODE 
RED
BLUE
N/A

BRIGHTNESS 
BRIGHTNESS
BRIGHTNESS 

LIMIT

1-70 (25)

1-70 (25)
1/60 -1/120,000

0-256 (32)
1-256 (39)

1-70 (25)
1-70 (25)
1-70 (25)

x2 - x128 (x8)

Содержание EasyView CD-S21N

Страница 1: ...SD Series w 36 LEDs Flush Housing w Surface Mount Plate Dome Cameras INSTALLATION MANUAL Indoor Wall Mount Pedestal Mount Junction Box Outdoor Wall Mount ...

Страница 2: ...all local codes 550 TV Lines 550 TV Lines Day Night IR LEDs CV FH Fan Heater for Vandalproof Domes CV WM Indoor Wall Mount CA OM Outdoor Wall Mount CA PM Pedestal Mount CA JB Junction Box CA SMC30 Service Monitor Cable About This Manual 3 Available Models 3 How to Open the Gimbal Cover 4 3 Axis Gimbal Adjustments 5 Assembly Mounting Accessories 6 Dimensions 7 Parts Name and Descriptions 8 Base Ins...

Страница 3: ... firmly in place with one hand Step 2 Gently press Points A B with other hand and pull the Gimbal cover off Step 3 Make necessary lens adjustments Refer to page 13 Step 4 Replace the Gimbal cover by gently pressing back onto the Gimbal base Gimbal Base Point A Point B Gimbal Cover EasyView Dome Cameras have vari focal lens integrated inside the Gimbal If you require to make focal focus adjustments...

Страница 4: ...over to flush housing Model Philips ST4x12 Qty 3 Length 12mm Thickness 4mm Mounting Screws For Vandalproof Indoor Domes These Screws are used to mount both surface mount plate or flush housing to a sturdy surface If necessary use the anchors included in the package Model Philips ST4x30 Qty 4 Length 30mm Thickness 4mm Anchors For Vandalproof Indoor Domes Qty 4 Length 30mm Thickness 6mm 144 99 Flush...

Страница 5: ...rews affix flush mount base to surface plate For flush mount application disregard this section 3 Flush Mount Using four ST4x30 screws affix flush mount base to a sturdy surface REMINDER Do not aim the camera directly into the sun 1 Lens 2 Power Input Connector 12VDC 24VAC Dual Voltage 3 Video Output Connector BNC 4 Service Monitor Output Connector Use Cable CA SMC30 5 Camera Control Board 6 Safet...

Страница 6: ...CV SD21P CV SD21N L CV SD21P L S Series SD Series 11 Dome Cameras Screws UNC 8 32 x 0 75 3 4 Pipe Note Screws required for electrical junction boxes are not supplied with the package These screws are readily available at local electrical supply stores Either flush mount or surface mount application pre drilled mounting holes on EasyView Domes accommodate various electrical junction boxes making in...

Страница 7: ... Monitor CA SMC30 30cm Left Right Up Right Down S Series SD Series Service Monitor Output 12 Connections N T W Adjust Focus Adjust Angle for Field of View Remove the Gimbal cover from the Gimbal base 1 Loosen Zoom Focus screws and make necessary adjustments as shown Field of View Telephoto T to Wide W Focus Near N to Far F 2 Please refer to Page 14 of this manual for further instructions 4 Replace...

Страница 8: ... Main Menu LENS SHUTTER WHITE BALANCE BACKLIGHT AGC DNR DSS Menu Setting Details DC MANUAL NONE FLK ESC MANUAL ATW MANUAL AWC OFF LOW MIDDLE HIGH OFF LOW MIDDLE HIGH OFF LOW MIDDLE HIGH OFF AUTO BRIGHTNESS BRIGHTNESS SHUTTER MODE RED BLUE N A BRIGHTNESS BRIGHTNESS BRIGHTNESS LIMIT 1 70 25 1 70 25 1 60 1 120 000 0 256 32 1 256 39 1 70 25 1 70 25 1 70 25 x2 x128 x8 ...

Страница 9: ...TOP DOWN LEFT RIGHT AREA SEL AREA 1 2 3 or 4 AREA STATE ON OFF TOP DOWN LEFT RIGHT LEVEL 0 31 8 17 OSD Menu Instructions OSD Menu Control CENTER KEY Used to access menu mode Also used to confirm the setting UP DOWN KEY Used to choose the desired menu selection LEFT RIGHT KEY Used to choose the desired menu feature adjustment OSD Menu ENTER EXIT A OSD MENU ENTER Pushing Center Key for 3 seconds B O...

Страница 10: ...C first before selecting Manual mode Once Manual mode is selected select SETUP Set the appropriate color temperature and increase or decrease the red and blue color values while monitoring the color changes on the object The Manual mode enables finer adjustment OSD Menu Instructions OSD Menu Instructions D BACKLIGHT This function is used when there is strong light in the background OFF Backlight C...

Страница 11: ...automatically converts to BW mode for night time BW The COLOR mode is operated for night time 21 OSD Menu Instructions SYNC This function is used when synchronization with the legacy system is needed INT Internal Synchronization LL External Synchronization Optional MOTION DETECTION This function detects all motion in a selected area OFF MOTION DETECTION mode is canceled ON Any motion in the select...

Страница 12: ...turns to the SETUP menu I EXIT Saves all the setting menus and then exits 22 Vandalproof Domes Power Input Power Consumption Heater Power Consumption Fan Heater ON Heater OFF Fan ON Note For Fan and Heater operation 24VAC power input is required Current model does not support 12VDC operation 24VAC 10W 0 7W at 41ºF 5ºC at 59ºF 15ºC 24 Hours Assembly Screw Philips M2 6x14 Qty 1 Length 14mm Thickness...

Страница 13: ...y Specifications are subject to change without any prior notice Video Formats Image Sensor Sync System Scanning system Electronic Shutter Main Video Output Service Monitor Output Horizontal Resolution Min Illumination S N Ratio Lens Options DC Auto Iris Auto Iris Control Camera Control Setup Operating Temperature Operating Humidity Weatherproof Power Consumption Power Requirement NTSC PAL 1 3 CCD ...

Страница 14: ...y Night Function 36 IR LEDs Option Lens Options DC Auto Iris Auto Iris Control Camera Control Setup Operating Temperature Operating Humidity Weatherproof Power Consumption Power Requirement NTSC PAL 1 3 CCD Internal Line Lock Optional 525 Lines Interlaced 625 Lines Interlaced 1 60 1 100 000 1 50 1 100 000 1 0 Vp p Composite 75 ohm 1 0 Vp p Composite 75 ohm 550 TV Lines Color 600 TV Lines B W 0 1 L...

Страница 15: ...meras NUVICO Tel 7 495 234 3212 Fax 7 495 234 3212 E mail techsupport nuvico ru www nuvico ru NUVICO EasyView and the NUVICO logos are registered trademarks of NUVICO Copyright 2008 NUVICO All rights reserved ...

Отзывы: