INSTALLATION
Alarm Connection
ALARM SENSOR
ALARM BUZZER
NOTE: To make connections on the Alarm Connector Strip, press and hold the button and insert the wire in the hole
below the button. After releasing the button, tug gently on the wire to make certain it is connected. To disconnect a wire,
press and hold the button above the wire and pull out the wire.
You can use external devices to signal the DVR to react to events. Mechanical or electrical switches can be wired to the
NUMBER 1-16 (Alarm-In) and G (Ground) connectors. The threshold voltage is 4.3V and should be stable at least 1
second to be detected. See the alarm menu of the event for configuring alarm input.
Connect the device to the C and NC (Normally Closed) connectors or C and NO (Normally Open) connectors.