11.7 Checking the Oil Level
The compressor must be placed on a solid surface with a tilt of no more than 5°.
The oil level must be checked every 5 working
hours of the compressor.
The oil level must be between the minimum and
the maximum shown on the oil level indicator.
(See close-up picture bottom of next page)
If the oil level is above the maximum level:
•
Position a recipient under the drain hose so
that the oil flows into the exhausted oil
recipient.
•
Open the drain valve and let the oil flow out
until the oil level returns within the max. and
min. limits
•
Close the drain valve.
If the oil level is below the minimum level:
•
Open the top fill plug
•
Top off with oil until the level returns within the max. and min. limits
•
Close the fill plug.
After running the compressor, the lubricant will be very hot. Take care when removing the
drain plug and draining the lubricant to avoid burns.
Recommended Nitrox Compressor Lubricant is changed when the first 25 hours of use is
reached, then change lubricant in 100 hour cycles or annually.
Wear gloves when handling compressor lubricant. If contact with skin is made, wash the skin
surface with soap and water.
Always wear goggles when handling compressor lubricant. These materials can cause eye
irritation. If you accidentally get lubricant into your eyes, flush with fresh water for 15 minutes
and contact a physician if irritation develops.
Compressor lubricant should be incinerated after use in a licensed facility in accordance with
Federal, State, and local regulations.
Lubricant
Fill Plug
Oil Level
Indicator
Oil drain
valve