Nuvair Open Electric Models
Nuvair Page 16
www.Nuvair.com
6.0
Compressor Specifications
Ambient room temperature should never exceed 113
o
F (45
o
C) during operation of the
Compressor System. Operation at higher temperatures may lead to system damage and
malfunction.
6.1
Unpack and Installation
1) Please read all information supplied before physically installing the Compressor System.
2) Unpack the system and remove from the pallet. Visually inspect the system to make sure there has
been no damage during shipping. If damaged, please call Nuvair to file a damage report. Please
take photos and supply detailed information about the damage.
3) Place the system in a permanent location allowing a minimum spacing of 36” from adjacent walls.
Select a location where ambient room temperature is a minimum of +41°F to a maximum +113°F
(°C Min. +5° - Max. +45°).
4) Make sure the installation space is well ventilated.
MCH 22
MCH 30
MCH 36
Charging Rate
Filling an 80 cu ft tank from 500 psi
15.8 SCFM (447 L/min)
20.4 SCFM (577 L/min)
27 SCFM (764 L/min)
Electrical Power Requirements
208-220 V / E1 / 60 Hz
208-230 V / E3 / 60 Hz
380-415 V / E3 / 50 Hz
440-480 V / E3 / 60 Hz
46 Amps 10 hp (7.4 kW)
28 Amps 10 hp (7.4 kW)
17 Amps 10 hp (7.4 kW)
17 Amps 10 hp (7.4 kW)
N/A
31 Amp 15 hp (11KW)
18 Amp 15 hp (11KW)
16 Amp 15 hp (11KW)
N/A
48 Amp 20 hp (15KW)
29 Amp 20 hp (15KW)
25 Amp 20 hp (15KW)
Max Operating
Pressure
Up To 6000 psi (414 bar)
Pumping Unit RPM
880
1100
1300
Number of Stages
4
4
4
Lubrication
Pressure Lubrication, capacity 4 L
Oil Pressure
58 psi,4 bars
21.75 psi, 1.5 bars
14.5 psi, 1 bar
cold
routine use
minimum pressure
Air Quality
Grade E