background image

www.NutrichefKitchen.com

14

Remove the screws holding the bottom cover plate, using a Phillips screwdriver. Disconnect the power 
cord quick connector (#1). Loosen the two hose clamps (#2 and #3) and remove the hoses from the pump. 
Unscrew the screw attaching the 2 ground cables (#4), and finally, loosen the screw attaching the pump. 
You can now remove the pump.

To access the impeller you need to unscrew the screws holding the pump front casing. Lift the front casing 
off to clean it on the inside. The impeller, the impeller shaft and the O-ring should also be removed for 
cleaning.

Use the procedure for removing but in reverse order to assemble all parts. Ensure that all parts in the 
pump housing are properly attached before tightening the screws. Ensure that both ground cables are 
attached to the fastening screw (#4).

Fault Indication:

If during the use of the machine, the machine turns off the power automatically, and the failure code 
appears on the display at the same time:

E1:

 Indicates temperature probe failure. Please check whether the probe (sensor) on the bottom plate is   

       kept clean, not covered or stuck by sediment or stains, or open the bottom plate and check whether  
       the wire connection of temperature probe is loose on the PC board.

E2:

 The temperature sensor is broken and needs to be replaced.

E3:

 Indicates that the thermostat has detected a dry-boil and shut down. 

        

The following three occasions may cause this fault normally, which needs to be checked and    

        confirmed:

 

        

A. 

No water or very little water inside of the brew kettle before start to heating; 

        

B.

 During brewing, some chocolate malt or black malt is ground into powder due to its crispness or 

         

             

the malt is ground up. The powder passes through the screen or surrounding crevices to the bottom,  

             

forming a layer of silt to cover the whole heating area or temperature probe. In this case, pour out  

             

the wort and take out the mash,clean the kettle,restart the machine.

E4:

 Means the temperature in the machine is overheated. The temperature exceeds the set temperature  

       of the thermostat and the thermostat fails. Let the machine stop working, disconnect the power    
       supply, wait for the machine to cool completely, then restart.

Front Casing

Impeller

Shaft

Magnet Capsule

O-Ring

Rear Casing

Drive Magnet

Содержание PKBRKTL200

Страница 1: ...PKBRKTL200 with Inner Malt Pipe and Filter Screen Home Beer Brewing Machine ...

Страница 2: ...eplacement Do not immerse the base of the unit in water Ensure that the brew kettle is placed on a flat surface and is stable during use Ensure proper handling when lifting the malt basket during brewing The weight of the malt basket including soaked malt can be up to 30Kgs Please note that the bottom part of the malt basket can have some rough edges Handle with care Close the tap and riser pipe v...

Страница 3: ...using the pump Turn valve handle horizontally to close and vertically to open The tap is used for emptying the boil kettle for any liquid The stainless steel tap is special made in a larger diameter and shorter outlet in order to have a bigger and quicker flow Please note that the handle can get hot To use the CamLock fittings connect the lid hose female CamLock fitting to the riser pipe male CamL...

Страница 4: ...well With the silicon hose connected to the riser pipe the pump can be used to circulate the wort during mashing and lautering The lid has an extra hole intended to be used in conjunction with a thermometer This allows for measuring the temperature in the mash at the top of the kettle as the temperature here sometimes be different from that on the bottom where the built in temperature sensor is lo...

Страница 5: ...pump assembly disassembly described later in this user manual and check silicon hose and fittings If there are no indications of any leakages connect the lid hose CamLock connector to the riser pipe place the lid on top of the boiler and connect the power cord to a wall outlet The built in light in the brew program selector will now illuminate Malt basket handle and filter screen bottom When you c...

Страница 6: ...NG MACHINE CONTROLLER The Home Beer Brewing Machine has an easy to use built in controller that has been designed to support the three phases of brewing described above Each phase is completed by basically heating up and maintaining temperatures where each phase has a different function in the beer brewing process The phases are displayed as HEAT preheating MASH mashing LAUTER lauthering and BOIL ...

Страница 7: ... The mashing temperature will normally be described in the beer recipe Some brewers may want to do multi step mashing mashing using several different temperature and steps This is possible to achieve too it can have 5 steps mashing at most THE BREW CONTROLLER DISPLAY EXPLAINED 1 Current temperature reading determined by a sensor in the bottom of the brew kettle Will display ambient temperature whe...

Страница 8: ...perature default 71 C it is adjustable The power during heating is 100 This is not adjustable M1 M5 There are 5 steps during mashing they are optional if you don t need it set its time as 0 this step will not run L Lautering phase default temperature 78 C 172 4 F power 60 and time 10 minutes All value are adjustable B1 B3 The steps for hopping during the boiling totally can have 5 steps to add hop...

Страница 9: ...under the program it can also jump directly and start to run from the step chosen by pressing the STEP key The steps with a timer setting of 0 or temperature setting of 0 are not run and are automatically skipped The flickering step in the top row on the display is the one currently running and the symbols of other unrunning steps are displayed in the top row but not blink this indicate that these...

Страница 10: ...mperature can be self set 30 100 C and the timing can be self set 0 999 minutes L default power 60 default temperature 78 C default timing 10 minutes After the operation is completed five alarm sounds are issued and then the machine is shut down B The operation of the selection program II PROG display II only When you select program II the machine will run the steps as the order of B1 B3 automatic...

Страница 11: ...he table above Three alarm sounds are issued after each M step is completed and enter next step 3 Operation L step the PHASE onthe display screen shows LAUTER the power can be self set 10 100 the temperature can be self set 30 100 C and the timing can be self set 0 999 minutes L default power 60 default temperature 78 C default timing 10 minutes After the operation is completed five alarm sounds a...

Страница 12: ...r you can pause at first and then restore the factory settings 8 Adjustment of temperature deviation temperature compensation function In standby or pause state keep press C F button for 5 seconds to enter the function of temperature deviation adjustment Pressing and button to modify the temperature deviation After determining the value press the SET button to save the settings The range of this d...

Страница 13: ...brew controller display switch the brew program selector to II then press Run Connect the whirlpool arm When the water is boiling open the riser pipe valve and switch on the pump and let it run for about 5 minutes in order to clean the equipment pipes and pump then switch the equipment off Empty the brew kettle dry of the equipment and store until your next brewing session Note Do not use a hard b...

Страница 14: ...whether the probe sensor on the bottom plate is kept clean not covered or stuck by sediment or stains or open the bottom plate and check whether the wire connection of temperature probe is loose on the PC board E2 The temperature sensor is broken and needs to be replaced E3 Indicates that the thermostat has detected a dry boil and shut down The following three occasions may cause this fault normal...

Страница 15: ... Necessary Installation Components Hardware Circulation System with Inner Pump WHAT S IN THE BOX Stainless Steel Kettle with Program Controller and Circulation System Glass Lid Inner Malt Pipe Filter Screen Lifting Handle CONSTRUCTION MATERIAL Food Grade 304 Stainless Steel 304 Stainless Steel Tap 304 Stainless Steel Circulation Pipe and Fittings Food Grade Pump with Silicon Tube Connection PP Bas...

Страница 16: ...Questions Issues We are here to help Phone 1 718 535 1800 Email support pyleusa com ...

Отзывы: