background image

www.NutrichefKitchen.com

12

5. Step Selection

     When the machine in standby or pause state, every time when pressing "

STEP

" button, the selected  

     STEP symbol will be blink in order on the screen, thus the power (wattage), temperature and timing  
     corresponding to the selected STEP can be set. You can also press the "

RUN/PAUSE

" key to RUN the  

     program backwards from the selected step. Program I can choose any step from all the step of S - L,  
     program II can choose any step from B1 to B3, program III can choose any step from all steps of S - B3.

6. Setting of power, temperature and timing

     When the machine in standby or suspended state, press "

STEP

" to select a step and reset the setting of  

     power, temperature and timing corresponding to this step.
     Every time to press "

SET

" button, the setting will follow below order to cycle, the icon corresponding  

     the selected symbol will blink, and then press (+) and (-) button to reset the value.

7. Restore default factory settings

     In the standby or pause state, keep press "

PROG

" button for 5 seconds to restore the factory settings,  

     the previous set procedures and settings will be eliminated from the machine. 
     

Note:

 in general, if the settings are wrong and memory or program is out of order, you can pause at  

     first and then restore the factory settings.

8. Adjustment of temperature deviation (temperature compensation function)

     In standby or pause state, keep press "

°C/°F

" button for 5 seconds to enter the function of temperature  

     deviation adjustment. Pressing (+) and (-) button to modify the temperature deviation. 
     After determining the value, press the SET button to save the settings. 
     The range of this deviation adjustment is within ±10°C.

Note:

 

1. This adjustment function is required in winter when the external environment temperature is too low,  
     the heat loss is too fast, or the water is boiling due to the high altitude, and the temperature cannot  
     reach 100°C/212°F  to enter the later program. 
2. If it is found that there is a big error between the display temperature and the measured temperature  
     during the course of using, the value can be adjusted and corrected through this function.

9. Conversion between Celsius and Fahrenheit °F

     Press "

°C/°F

" button at any time after starting up to convert the display of °C and Fahrenheit °F.

10. Power off protection function

     If there is an unexpected power failure after starting up, the machine will automatically remember the  
     breakpoint. When the power is switched on again, the breakpoint will be automatically found by the  
     machine. Press the "

RUN/PAUSE

" button to restart this step and continue to RUN the next step as    

     previous settings.

Temperature           Timing           Power

Содержание PKBRKTL200

Страница 1: ...PKBRKTL200 with Inner Malt Pipe and Filter Screen Home Beer Brewing Machine ...

Страница 2: ...eplacement Do not immerse the base of the unit in water Ensure that the brew kettle is placed on a flat surface and is stable during use Ensure proper handling when lifting the malt basket during brewing The weight of the malt basket including soaked malt can be up to 30Kgs Please note that the bottom part of the malt basket can have some rough edges Handle with care Close the tap and riser pipe v...

Страница 3: ...using the pump Turn valve handle horizontally to close and vertically to open The tap is used for emptying the boil kettle for any liquid The stainless steel tap is special made in a larger diameter and shorter outlet in order to have a bigger and quicker flow Please note that the handle can get hot To use the CamLock fittings connect the lid hose female CamLock fitting to the riser pipe male CamL...

Страница 4: ...well With the silicon hose connected to the riser pipe the pump can be used to circulate the wort during mashing and lautering The lid has an extra hole intended to be used in conjunction with a thermometer This allows for measuring the temperature in the mash at the top of the kettle as the temperature here sometimes be different from that on the bottom where the built in temperature sensor is lo...

Страница 5: ...pump assembly disassembly described later in this user manual and check silicon hose and fittings If there are no indications of any leakages connect the lid hose CamLock connector to the riser pipe place the lid on top of the boiler and connect the power cord to a wall outlet The built in light in the brew program selector will now illuminate Malt basket handle and filter screen bottom When you c...

Страница 6: ...NG MACHINE CONTROLLER The Home Beer Brewing Machine has an easy to use built in controller that has been designed to support the three phases of brewing described above Each phase is completed by basically heating up and maintaining temperatures where each phase has a different function in the beer brewing process The phases are displayed as HEAT preheating MASH mashing LAUTER lauthering and BOIL ...

Страница 7: ... The mashing temperature will normally be described in the beer recipe Some brewers may want to do multi step mashing mashing using several different temperature and steps This is possible to achieve too it can have 5 steps mashing at most THE BREW CONTROLLER DISPLAY EXPLAINED 1 Current temperature reading determined by a sensor in the bottom of the brew kettle Will display ambient temperature whe...

Страница 8: ...perature default 71 C it is adjustable The power during heating is 100 This is not adjustable M1 M5 There are 5 steps during mashing they are optional if you don t need it set its time as 0 this step will not run L Lautering phase default temperature 78 C 172 4 F power 60 and time 10 minutes All value are adjustable B1 B3 The steps for hopping during the boiling totally can have 5 steps to add hop...

Страница 9: ...under the program it can also jump directly and start to run from the step chosen by pressing the STEP key The steps with a timer setting of 0 or temperature setting of 0 are not run and are automatically skipped The flickering step in the top row on the display is the one currently running and the symbols of other unrunning steps are displayed in the top row but not blink this indicate that these...

Страница 10: ...mperature can be self set 30 100 C and the timing can be self set 0 999 minutes L default power 60 default temperature 78 C default timing 10 minutes After the operation is completed five alarm sounds are issued and then the machine is shut down B The operation of the selection program II PROG display II only When you select program II the machine will run the steps as the order of B1 B3 automatic...

Страница 11: ...he table above Three alarm sounds are issued after each M step is completed and enter next step 3 Operation L step the PHASE onthe display screen shows LAUTER the power can be self set 10 100 the temperature can be self set 30 100 C and the timing can be self set 0 999 minutes L default power 60 default temperature 78 C default timing 10 minutes After the operation is completed five alarm sounds a...

Страница 12: ...r you can pause at first and then restore the factory settings 8 Adjustment of temperature deviation temperature compensation function In standby or pause state keep press C F button for 5 seconds to enter the function of temperature deviation adjustment Pressing and button to modify the temperature deviation After determining the value press the SET button to save the settings The range of this d...

Страница 13: ...brew controller display switch the brew program selector to II then press Run Connect the whirlpool arm When the water is boiling open the riser pipe valve and switch on the pump and let it run for about 5 minutes in order to clean the equipment pipes and pump then switch the equipment off Empty the brew kettle dry of the equipment and store until your next brewing session Note Do not use a hard b...

Страница 14: ...whether the probe sensor on the bottom plate is kept clean not covered or stuck by sediment or stains or open the bottom plate and check whether the wire connection of temperature probe is loose on the PC board E2 The temperature sensor is broken and needs to be replaced E3 Indicates that the thermostat has detected a dry boil and shut down The following three occasions may cause this fault normal...

Страница 15: ... Necessary Installation Components Hardware Circulation System with Inner Pump WHAT S IN THE BOX Stainless Steel Kettle with Program Controller and Circulation System Glass Lid Inner Malt Pipe Filter Screen Lifting Handle CONSTRUCTION MATERIAL Food Grade 304 Stainless Steel 304 Stainless Steel Tap 304 Stainless Steel Circulation Pipe and Fittings Food Grade Pump with Silicon Tube Connection PP Bas...

Страница 16: ...Questions Issues We are here to help Phone 1 718 535 1800 Email support pyleusa com ...

Отзывы: