background image

Page 2

MODEL  QTXEN110SFLT   

TYPICAL INSTALLATIONS

Housing mounted to 

I

-joists.

Housing mounted anywhere 

between trusses using 

hanger bars.

PLAN THE INSTALLATION

1.  Choose the 

installation 

location.

The location of 

your humidity 

sensing 

fan is very 

important. Use 

the following 

guidelines for 

best operation:

Housing mounted anywhere 

between 

I

-joists using 

hanger bars.

Housing mounted to joists.

Housing mounted 

anywhere between 

joists using hanger bars.

Housing mounted anywhere 

between trusses using hanger 

bars.

INSTALL HOUSING & 
DUCT

1a. Mount 

housing 

to joist or 

I

-joist.

Use a pliers to 

bend housing 

TABS out 

to 90

0

. Hold 

housing in 

place so that 

the housing 

tabs contact 

the bottom 

of the joist. 

The housing 

mounts with 

four (4) screws 

or nails. Screw 

or nail housing 

to joist through 

lowest holes in 

each mounting 

flange,  then 

SPACER

(use for mounting to I-Joist)

TABS

I

-JOIST

through highest holes. NOTE: Mounting to 

I

-JOIST 

(shown) requires use of 

SPACERS (included) 

between the highest hole of each mounting flange 

and the 

I

-joist.

OR

•  Locate unit above (GFCI protected circuit required) or 

within 5 feet of shower head.

•  Locate unit away from heating or cooling sources 

which can affect humidity levels.

•  Do not locate near window. Unit may respond to the 

outdoor humidity level.

•  Unit must be installed in ceiling to properly sense 

moisture.

•  Locate unit only on flat ceilings up to 12 feet high for 

proper sensing.

•  The fan will operate most efficiently when located 

where the shortest possible duct run and minimum 

number of elbows will be needed.

2.  Plan the wiring.

•  Plan to supply the unit with proper line voltage and  

  appropriate power cable. Power cable should be  

  routed to the switch box first and then to the unit  

  (See “CONNECT WIRING” on page 3).

•  Do not operate this unit with a speed control.    

  Damage to the sensor unit will result.

•  Light or night-light may be installed with a wall-   

  mounted motion control.

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

6-IN. ROUND

DUCT*

6-IN.

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

Содержание QTXEN110SFLT

Страница 1: ...ghtly vacuum to clean sensor and grille DO NOT USE ABRASIVE CLOTH STEEL WOOL PADS OR SCOURING POWDERS 3 DO NOT USE cleaning sprays solvents or water on or near the sensor OPERATION The humidity contro...

Страница 2: ...t hole of each mounting flange and the I joist OR Locate unit above GFCI protected circuit required or within 5 feet of shower head Locate unit away from heating or cooling sources which can affect hu...

Страница 3: ...NAL SCREW MOUNTING 4 MOUNTING CHANNEL 2 NAIL 4 BOTTOM EDGE OF FRAMING 1 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wir...

Страница 4: ...air or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does no...

Страница 5: ...OS ALMOHADILLAS DE LANA DE ACERO NI POLVOS ABRASIVOS 3 NO USE sprays limpiadores solventes ni agua en o cerca del sensor OPERACI N El control de humedad y el ventilador pueden funcionar separadamente...

Страница 6: ...a obtener una detecci n adecuada de humedad El ventilador funcionar m s eficientemente cuando se ubique en un rea en la que se necesite el tramo m s corto de conductos posible y un n mero m nimo de co...

Страница 7: ...OCHE ENCENDIDO APAGADO L NEA DE ENTRADA DE 12O V CA CAJA DEL CONMUTADOR UNIDAD CONTROL DE HUMEDAD VENTILADOR OPCI N DE CONEXI N n 1 OPCI N DE CONEXI N n 2 El ventilador se puede encenderse apagarse o...

Страница 8: ...RRANCADORES NI A TUBOS DE LAS L MPARAS FLUORES CENTES Esta garant a no cubre a mantenimiento y servicio normales ni b ning n producto o piezas que se hayan sometido a uso inadecuado negligencia accide...

Отзывы: