READ & SAVE THESE INSTRUCTIONS!

INSTALLATION INSTRUCTIONS

®

Bathroom Exhaust
Fan/Light
Combination

• Suitable for use in insulated ceilings.
• Not for use in kitchens.
WARNING: To reduce the risk of fire or electrical shock, do not

use this fan with any solid-state speed control
device.

WARNING: To reduce the risk of shock, disconnect power

before servicing.  Do not install in a ceiling insulated
to a value greater than R-40.

IMPORTANT SAFETY INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at Service

Panel and lock Service Panel to prevent power from being
switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a tag, to the
service panel.

CAUTION:

For general ventilating use only. Do not use to exhaust

hazardous or explosive materials and vapors.

INSTALLATION INSTRUCTIONS

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:

A. Installation work and electrical wiring must be done by qualified

person(s) in accordance with all applicable codes and standards,
including fire-rated construction.

B. Sufficient air is needed for proper combustion and exhausting of

gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage

electrical wiring and other hidden utilities.

D. Ducted fans must always be vented to the outdoors.
E. If this unit is to be installed over a tub or shower, it must be

marked as appropriate for the application.

F. NEVER place a switch where it can be reached from a tub or

shower.

MODEL: 8663RM SERIES

Suitable for use in shower or tub enclosure when used
with a GFI circuit.

FOR BEST RESULTS

When installing the Exhaust Fan/Light in a new construction site,

install housing during the rough-in construction of the building. The
blower unit and grille should be installed after the finished ceiling is 
in place.

PLANNING DUCTWORK AND WIRING

DUCTWORK

1. Use 4" round duct.
2. Plan duct run from discharge opening of fan to the outside.
3. Use optional NuTone ducting accessories as needed. Refer to

NuTone's catalog for a complete listing of available accessories.

WIRING

IMPORTANT: 

Use wire suitable for 90°C.

Plan to run 120vAC house wiring (with ground) from power source,

through wall switch, to junction box in fan housing. For separate
control of fan, and light use an optional NuTone switch.

INSTALLATION IN A NEW
CONSTRUCTION SITE

PREPARATION

1. 

Refer to Figure 1. 

Remove power unit/blower assembly from

housing.
A. Unplug power unit.
B. Remove screw (located next to plug-in receptacle) which holds

power/blower unit mounting plate in place. Save screw.

C. Lift mounting plate at end near the plug-in receptacle until

blower wheel clears the scroll.

D. Remove plate by pulling its tabs out of slots in housing. Set

power/blower unit aside until needed.

2. Remove one of the wiring knockouts from housing.

MOUNTING THE HOUSING

MOUNTING USING MOUNTING TABS
Refer to Figure 2.

1. Locate fan housing next to ceiling joist.
2. Use wood screws (not provided) to loosely attach housing to ceiling

joist through keyhole slots in mounting tabs.

3. Adjust housing so that it will be flush with finished ceiling. For the

grille to fit properly, the housing's rim must not extend beyond
finished ceiling surface.

4. When housing is properly adjusted, tighten screws in slots.

MOUNTING USING HANGER BARS

Refer to Figure 3.

1. Insert hanger bars in slots provided in housing.
2. Locate fan housing between joists so that the bottom of the

housing is even with the planned finished ceiling. Extend the
hanger bars to the joists.

3. Use screws or nails (not provided) to secure hanger bars to ceiling

joists.

INSTALLING DUCTWORK

1. 

Refer to Figure 1. 

Place duct collar over flanges at discharge

opening of fan. Secure collar by snapping tabs into slots in flanges.

2. Run 4" round duct from fan's discharge opening to the outside and

terminate.

3. Connect duct to fan's duct collar.

Содержание 8663RM Series

Страница 1: ...for use in shower or tub enclosure when used with a GFI circuit FOR BEST RESULTS When installing the Exhaust Fan Light in a new construction site install housing during the rough in construction of t...

Страница 2: ...to be sure that 1 Ducting can be installed or that area is sufficient for proper venting 2 Wiring can be run to the planned location 3 No wiring or other obstruction might interfere with installation...

Страница 3: ...etapa de enterramiento de la linstalaci n el ctrica de la construcci n La unidad de potencia el reflector y la rejilla deben de instalarse despu s de que el techo acabado est en su sitio PLANIFICACION...

Страница 4: ...es de continuar con la instalaci n Refi rase a la Figura 4 para el cableado y a la Figura 3 para el conducto PRECAUCION compruebe el rea sobre la instalaci n planeada para asegurarse de que 1 El condu...

Страница 5: ...la grille doivent tre install s apr s la finition du plafond PREPARATION DU GAINAGE ET DU CABLAGE GAINAGE 1 Utiliser une gaine ronde de 4 pounces 2 Pr voir le parcours de la gaine pour vacuation l ex...

Страница 6: ...l installation Voir Figure 4 pour le c blage et Figure 3 pour le gainage ATTENTION Inspector l espace au dessus de l emplacement pr vu pour s assurer que 1 La gaine puisse tre install e ou que l espa...

Страница 7: ...USE WIRING Cabledo De La Casa De 120vCA COURANT DOMESTIQUE 120 V AC DUCT COLLAR Collarn Del Conducto COLLIER DE GAINE WIRING KNOCKOUT Agujero Ciego Del Cableado PREDECOUPE DE CABLAGE MOUNTING HOLES Ag...

Страница 8: ...PECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or ex...

Страница 9: ...6310 RETAINING RING LENS SPRING ASSY 8663RMSA 8663RMBR 86310 000 86311 RETAINING RING LENS SPRING ASSY 8663RMAB 86311 000 12 16133 WING NUT 8663RM SERIES 16133 000 13 10034 FAN RECEPTACLE 8663RM SERIE...

Отзывы: