NuTone 742RBNT Скачать руководство пользователя страница 2

Page 2

MODELS  742RBNT • 742WHNT • 742SNNT

3. Set housing aside and drive nails partially into joist at the

top of both keyhole marks.

4. Hang housing from nails and pound nails tight. To ensure

a noise-free mount, pound another nail through the top
hole of each mounting tab.

INSTALL THE  HOUSING
(continued)

New Construction

Existing Construction

2. In attic, position mounting brackets against joist. Trace

outline of housing on ceiling material.

1. Choose the location for your fan/light in the ceiling. For

best possible performance, use the shortest possible duct
run and a minimum number of elbows.

3. Set housing aside and cut ceiling opening slightly larger

than marked.

TYPICAL INSTALLATIONS
(continued)

SUSPENDED CEILINGS

Housing hung with wires - 3-point mount.

MOUNTING

TAB

GRILLE

PAN

SUSPENDED

CEILING

MATERIAL

POWER

CABLE

4" ROUND

DUCT

HOUSING

GLASS

LIGHT SHADE

INSTALL THE  HOUSING

1. Choose the location for your fan in the ceiling. For best

possible performance, use the shortest possible duct run
and a minimum number of elbows.

2. Position mounting brackets against joist so that bottom

edge of housing will be flush with finished ceiling.

Additional positioning feature for 5/8”, 1”, &
1-1/4” thick ceiling material:

Holes in corners of housing are labeled with various
ceiling material thicknesses. Position housing so
bottom edge of joist is visible through a matched
set of holes. The housing is now in the proper
position for that ceiling material thickness.

Additional positioning feature for 1/2” thick
ceiling material:

Bend two tabs, on side of housing, 90

0

 outward. Lift

housing until tabs contact underside of joist.

Mark the keyhole slot on both mounting brackets.

New Construction

5/8

1

1-1/4

TAB

HOLES

BOTTOM EDGE OF JOIST

- PLEASE NOTE -

THE FOLLOWING INSTALLATION ILLUSTRATIONS SHOW 2 X 6
JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST INSTALLATION,
MOUNT THE VENTILATOR TO THE ADDITIONAL FRAMING IN
THE SAME MANNER. (Additional framing must be a 2x6 (mini-
mum height), at least 9-inches long.)

Содержание 742RBNT

Страница 1: ...installation in ceilings up to a 12 12 pitch Ductwork must point up DO NOT MOUNT THIS PRODUCT IN A WALL 3 The light fixture assembly must be mounted to thefanhousingassemblyincludedwiththisprod uct Do not mount the light fixture assembly to a wiring outlet box 4 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 5 Please read...

Страница 2: ...the location for your fan in the ceiling For best possible performance use the shortest possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1 1 1 4 thick ceiling material Holes in corners of housing are labeled with various ceiling material thicknesses P...

Страница 3: ...es stan dards Theslightestbackdraft however willclosethedamper flap preventing air from entering unit or finished space 4 Place housing in opening so that its bottom edge is flush with finished ceiling Nail to joist through keyhole on both sides To ensure a noise free installation drive another nail through the top hole of each mounting bracket Existing Construction 5 Additional mounting holes are...

Страница 4: ...to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you NUTONE SOBLIGATIONTOREPAIRORREPLACE ATNUTONE SOPTION SHALLBETHEPURCHASER SSOLEANDEXCLUSIVEREMEDYUNDERTHISWARRANTY NUTONESHALLNOTBELIABLEFORINCIDENTAL CONSEQUENTIAL ORSPECIALDAMAGESARISINGOUTOFORINCONNECTIONWITHPRODUCTUSE...

Страница 5: ...PARED 3 Elconjuntodelaluzsedebemontaralmontajeelconjuntocaja del ventilador incluido con este producto No montaje el conjuntodelaluzaunacajadelenchufedelcableado 4 Paraevitarcausardañoaloscojinetesdelmotorypistones impulsores ruidosos y o no balanceados mantenga los aerosolesparapirca elpolvodeconstrucción etc lejosdel motor 5 Por favor consulte la información y los requerimientos adicionalesconte...

Страница 6: ...DE LA VIGUETA 2 Coloque las abrazaderas de montaje contra la vigueta de ma nera que el borde inferior de la cubierta quede al ras del cielo raso terminado Característica adicional para la colocación en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubierta están marcados con varios espesores del material del cielo raso Coloque la cub...

Страница 7: ...debe quedar al ras de la parte superior de la cubierta 2 Conecte el conducto redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exterior a través de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que abre libremente Coloque cinta en todas las conexiones de los conductos para asegurarlas y hacerlas herméticas Página 7 ARME...

Страница 8: ...trariaalasinstruccionesdeinstalaciónrecomendadas Laduracióndecualquiergarantíaimplícitaselimitaaunperíododeunañocomoseespecificaenlagarantíaexpresa Algunosestadosnopermitenlimitacionesencuantoaltiempodeexpiracióndeunagarantíaimplícita porloquelalimitaciónantesmencionadapuedenoaplicarse a usted LAOBLIGACIONDENUTONEDEREPARAROREEMPLAZAR SIGUIENDOELCRITERIODENUTONE DEBERASERELUNICOYEXCLUSIVORECURSOLEG...

Отзывы: