background image

 

   Operating Instruction and Documentation 

                                                                                                                                  UNI-LIFT 2500 

 

 

- 18 - 

   

A regular and appropriate maintenance practice will aid the preservation of the lift. 

No guarantees can be given when damage (egg rust or fading colour) is the direct result of poor 

maintenance and cleaning practice. 

Regular cleaning of all kinds of dirt is the best protection against wear and the formation of rust 

and will prolong the life of the lift 

 

- Dirty deposits that can cause rust include: 

• de-icing 

salt 

•  sand, pebble stone, natural soil 

•  all types of industrial dust  

•  water; also in connection with other environmental influences 

•  all types of aggressive deposits 

•  constant humidity caused by insufficient ventilation 

Obviously this is dependent on the type of work being done with the lift, the degree of 

cleanliness of the workshop and location of the lift. The degree and amount of dirt is dependent 

on the season, on the weather conditions and the ventilation of the workshop. 

During poor conditions it may be necessary  to clean the lift once week, but cleaning once a 

month will suffice. 

 

Clean the lift and the floor with a non-aggressive and  non-abrasive detergent. Use a gentle 

detergent to clean the parts. Use an standard washing-up liquid and lukewarm water.  

-  Do not use steam jet cleaners. 

-  Remove all dirt carefully with a sponge or if necessary with a brush. 

-  Ensure that no washing-up liquid is left on the lift after cleaning.  

-  Do not use aggressive means for cleaning the workshop floor and the automotive lift.  

-  A permanent contact with any kind of liquid is not allowed. Do not use high 

pressure devices

 

for cleaning the lift.

 

 

8. Security check 

 

The security check is necessary to guarantee the safety of the lifting during use. It has to be 
performed in the following cases: 
 
1.  Before the initial operation, after the first installation 

Use the form “First security check before initiation” 

2.  In regular intervals after the initial operation, at least annually. 

Use the form “Regular security check at least annually” 

3.  Every time the construction of that particular lift has been changed. 

Use the form “Extraordinary security check” 
 

The first and the regular security check must be performed by a competent person. It 
is recommended to service the lift at this occasion.

 

 

After the construction of the lift has been changed (changing the lifting height or 
capacity for example) and after serious maintenance works (welding on carrying 

parts) an extraordinary security check must be performed by an expert. 
 

This manual contains form with a schedule for the security checks. Please us the adequate form 
for the security checks. The form should remain in this manual after they have been filled out. In 
the following there is a short description about special safety devices.

 

 

Содержание UNI-LIFT 2500

Страница 1: ...2006 Operating Instruction and Documentation Serial number Nu baum Hebetechnik GmbH Co KG Korker Stra e 24 D 77694 Kehl Bodersweier Tel 49 0 7853 8990 Fax 49 0 7853 8787 E mail info nussbaum lifts de...

Страница 2: ...ns 12 5 Operating instructions 12 5 1 Lifting the vehicle 12 5 2 Lowering the vehicle 13 5 3 Equalisation of the rails 13 6 Troubleshooting 14 6 1 Driving on an obstacle 14 6 2 Emergency lowering 15 7...

Страница 3: ...the lift Especially the chapter Safety accident Prevention has to be observed In addition to the safety remarks of the instructions for use the regulations and instructions being valid at the place of...

Страница 4: ...nd time intervals including Details for exchange of parts part components as mentioned in the instructions for use are to be adhered These works must only be carried out by expert personal After maint...

Страница 5: ...ety was checked and the lift was started The installation was effected from the operating authority competent please delete as applicable The safety of the automotive lift was checked from the compete...

Страница 6: ...was started The persons below were introduced after the installation of the automotive lift The introduction was carried out from an erector of the lift manufacturer or from a franchised dealer compe...

Страница 7: ...lift They are called experts and competent persons in this document Experts are persons for example self employed engineers experts which have received instruction and have experience to check and to...

Страница 8: ...lift or on the vehicle It s not allowed to install the standard automotive lift in a hazardous location or washing bays After changes of the construction after essential maintenance work on carrying...

Страница 9: ...Operating Instruction and Documentation UNI LIFT 2500 9 2 5 Page for notice...

Страница 10: ...valve ca 255 bar with 2500 kg Oil tank approx 11 Litre Sound level 75 dBA Connection by customer 3 N PE 400V 50 Hz standard version with fuse T16A Pay attention to the voltage of your state 3 2 Safety...

Страница 11: ...Operating Instruction and Documentation UNI LIFT 2500 11 3 3 Data sheet...

Страница 12: ...ssengers on the lift or in the vehicle It s not allowed to climb onto the lift or onto a lifted vehicle The automotive lift must be checked from an expert after changes in construction or after repair...

Страница 13: ...its lowest fully collapsed position 5 3 Equalisation of the rails Continuous duty of the lift without reaching the lowest position there might be an un equalisation of the two rails functionally Norma...

Страница 14: ...ive hydraulic valve Gear pump is defective Coupling from the motor is faulty Solution unload the vehicle refills check the screws Call the service partner Call the service partner Call the service par...

Страница 15: ...t an object wood height 30 mm between the hydraulic cylinder and the safety ratchet so the teeth of the ratchets can not engaged in the ratchet strip see Pic Make these process on both cylinder Pic 3...

Страница 16: ...bricate the moving parts of the lift hinge bolts sliding pieces sliding surfaces grease with a multipurpose lipid example Auto Top 2000 LTD Agip Grease the lubricate nipples with a multipurpose lipid...

Страница 17: ...ter this is complete use a suitable paint observe the RAL Number Check the zinc surface and repair it with a suitable tool Use abrasive paper grain 280 White rust can result from moisture laying in ce...

Страница 18: ...all dirt carefully with a sponge or if necessary with a brush Ensure that no washing up liquid is left on the lift after cleaning Do not use aggressive means for cleaning the workshop floor and the a...

Страница 19: ...recommended Plug type connection bay customer If the plug type connection is on a height of about 2 meter and only approachable with devices In this case it is necessary to fasten a separate lockable...

Страница 20: ...dowels with the dynamometric key M 80Nm Each Liebig dowel must be tightened with the demanded torque Otherwise the normal and secure function of the lift can not guaranteed Observe the regulations of...

Страница 21: ...e blind plugs to close the hoses Disconnect the power supply Transport the lift to its new place Install the lift in accordance with chapter 9 Installation and Initiation Equalize and deaerate the lif...

Страница 22: ...ehe den aktuellen Fundamentplan see current foundation diagram drawing vois le plan de fondation actuel Bohrerdurchmesser diameter of bore Diam tre de l al sage do 15 18 24 Bauteildicke thickness of t...

Страница 23: ...owel type B20 75 B20 100 Drilling depth a 115 140 Min anchorage depth b 85 85 Thickness of concrete c 180 180 Diameter of bore d 20 20 Thickness of the lift pieces e 0 40 40 65 Number of dowels 12 12...

Страница 24: ...135 B20 175 Drilling depth a 140 165 175 215 Min anchorage depth b 85 85 85 85 Thickness of concrete c 180 180 180 180 Diameter of bore d 20 20 20 20 Thickness of the lift piece e 40 65 65 90 90 100 1...

Страница 25: ...anufacturer after installation 9 6 Change of lift location If the place of installation is to be changed the new place has to be prepared in according to the regulations of the first installation The...

Страница 26: ...control valve 4 filling plug 5 equalisation lever ball valve 6 hydraulic pressure switch SL tube return in the tank H1 tube lifting KL tube ratchet D1 tube equalisation pic 9 connection the hydraulic...

Страница 27: ...ing F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F...

Страница 28: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 29: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 30: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 31: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 32: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 33: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 34: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 35: ...ng F F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F...

Страница 36: ...F F Torque of the dowels and screws F F F Fixed seat of the screws F F F Condition surface piston rod F F F Condition coverings F F F Condition electrical wires F F F Level of hydraulic oil F F F Cond...

Страница 37: ...Operating Instruction and Documentation UNI LIFT 2500 37 Electrical diagram drawing...

Страница 38: ...Operating Instruction and Documentation UNI LIFT 2500 38...

Страница 39: ...Operating Instruction and Documentation UNI LIFT 2500 39...

Страница 40: ...r erreichbar mit Hilfsmitteln z b einer Leiter muss ein separater abschlie barer Hauptschalter in erreichbarer H he angebracht werden Plug type connection bay customer If the plug type connection is o...

Страница 41: ...Operating Instruction and Documentation UNI LIFT 2500 41...

Страница 42: ...Operating Instruction and Documentation UNI LIFT 2500 42...

Страница 43: ...Operating Instruction and Documentation UNI LIFT 2500 43...

Страница 44: ...Operating Instruction and Documentation UNI LIFT 2500 44 Hydraulic diagram drawing...

Страница 45: ...r 400 V 50 Hz 3 kW 0 4 gear pump 3ccm revolution 0 5 oil filter 0 6 hydraulic block 0 7 pressure relief valve 0 8 4 3 way valve 0 9 holding valve 0 10 screen 0 11 hydraulic pressure switch 0 12 screen...

Отзывы: