OPI-POWER LIFT HF 3S 12000-V1.0-EN
31
Time frame
Maintenance
type position
Person in
charge
Maintenance plan
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
E
F
G
Trained ser-
vice personnel
The booms and bolts of the lifting arm and the thread-
ed bolts of the carrier plate are to be checked for ease
of running. If required, lightly grease with a multi-pur-
pose grease.
Do not over-lubricate.
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
H
Trained ser-
vice personnel
• Check the torque of the fastening anchor. See the
data sheet for the relevant anchor manufacturer.
• Check the torque of the fastening screws. Also see
the assembly protocol.
Torque (Nm) for shaft screws
Fastening class 8.8
0,08* 0,12** 0,14***
M8
17,9 23,1 25,3
M10
36 46 51
M12
61 80 87
M16
147 194 214
M20
297 391 430
M24
512 675 743
Fastening class 10.9
0,08* 0,12** 0,14***
M8 26,2 34
37,2
M10
53 68 75
M12 90
117
128
M16
216 285 314
M20
423 557 615
M24
730 960 1060
*
Lubricated slide friction number 0.8 MoS2
**
Lightly oiled slide friction number 0.12
***
Ensured slide friction number 0.14 screw with micro-encap-
sulated plastic
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Trained ser-
vice personnel
All weld seams must have a visual inspection. Stop
the system and contact the manufacturer if there are
cracks or breaks in weld seams..
Annually
1
12
11
10
9
8
7 6 5
4
3
2
1 x / 12
Check all available safety devices for function.
Содержание HF 3S 12000
Страница 2: ...2 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Страница 4: ......
Страница 19: ...OPI POWER LIFT HF 3S 12000 V1 0 EN 19 ...
Страница 20: ...20 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Страница 21: ...OPI POWER LIFT HF 3S 12000 V1 0 EN 21 ...
Страница 22: ...22 OPI POWER LIFT HF 3S 12000 V1 0 EN ...
Страница 53: ...Made in Germany POWER LIFT HF 3S 12000 Made in Germany Spare parts list ...
Страница 60: ...60 OPI POWER LIFT HF 3S 12000 V1 0 EN 60 xx Switch box 000STA03600 2 05 07 19 ...